T1 - Impact of Pulsatile Flow Settings on Hemodynamic Energy Levels Using the Novel Diagonal Medos DP3 Pump in a Simulated Pediatric Extracorporeal Life Support System
AU - Adedayo, Pelumi
AU - Wang, Shigang
AU - Kunselman, Allen R.
AU - Ündar, Akif
N1 - Funding Information:
The author(s) disclosed receipt of the following financial support for the research, authorship, and/or publication of this article: This study was supported by Penn State Hershey College of Medicine, Department of Pediatrics seed funds (AÜ).
PY - 2014/7
Y1 - 2014/7
N2 - The objective of this study was to evaluate the pump performance of the novel diagonal Medos Deltastream DP3 diagonal pump (MEDOS Medizintechnik AG, Stolberg, Germany) under nonpulsatile to pulsatile mode with varying differential speed values in a simulated pediatric extracorporeal life support system. The experimental circuit consisted of a Medos Deltastream DP3 pump head and console, a Medos Hilite 2400 LT hollow fiber membrane oxygenator (MEDOS Medizintechnik AG), a 14F Medtronic DLP arterial cannula (Medtronic Inc, Minnesota), and a 20F Terumo Tender Flow Pediatric venous return cannula (Terumo Corporation, Michigan). Trials were conducted at flow rates ranging from 500 mL/min to 2,000 mL/min (500 mL/min increments) and pulsatile differential speed values ranging from 500 rpm to 2,500 rpm (500 rpm increments) using human blood (hematocrit 35%). The postcannula pressure was maintained constantly at 60 mm Hg. Real-time pressure and flow data were recorded using a custom-made data acquisition system and Labview software. Under all experimental conditions, pulsatile flow (P) generated significantly greater energy equivalent pressure (EEP), surplus hemodynamic energy (SHE), and total hemodynamic energy (THE) than those of nonpulsatile flow (NP). Under NP, SHE was zero. Higher differential speed values generated greater EEP, SHE, and THE values. There was little variation in the oxygenator pressure drop and the cannula pressure drop in P, compared to NP. The novel Medos Deltastream DP3 diagonal pump is able to generate physiological quality of P, without backflow. With increased differential rpm, the pump generated greater EEP, SHE, and THE. Physiological quality of pulsatility may be associated with better microcirculation because of greater EEP, SHE, and THE.
AB - The objective of this study was to evaluate the pump performance of the novel diagonal Medos Deltastream DP3 diagonal pump (MEDOS Medizintechnik AG, Stolberg, Germany) under nonpulsatile to pulsatile mode with varying differential speed values in a simulated pediatric extracorporeal life support system. The experimental circuit consisted of a Medos Deltastream DP3 pump head and console, a Medos Hilite 2400 LT hollow fiber membrane oxygenator (MEDOS Medizintechnik AG), a 14F Medtronic DLP arterial cannula (Medtronic Inc, Minnesota), and a 20F Terumo Tender Flow Pediatric venous return cannula (Terumo Corporation, Michigan). Trials were conducted at flow rates ranging from 500 mL/min to 2,000 mL/min (500 mL/min increments) and pulsatile differential speed values ranging from 500 rpm to 2,500 rpm (500 rpm increments) using human blood (hematocrit 35%). The postcannula pressure was maintained constantly at 60 mm Hg. Real-time pressure and flow data were recorded using a custom-made data acquisition system and Labview software. Under all experimental conditions, pulsatile flow (P) generated significantly greater energy equivalent pressure (EEP), surplus hemodynamic energy (SHE), and total hemodynamic energy (THE) than those of nonpulsatile flow (NP). Under NP, SHE was zero. Higher differential speed values generated greater EEP, SHE, and THE values. There was little variation in the oxygenator pressure drop and the cannula pressure drop in P, compared to NP. The novel Medos Deltastream DP3 diagonal pump is able to generate physiological quality of P, without backflow. With increased differential rpm, the pump generated greater EEP, SHE, and THE. Physiological quality of pulsatility may be associated with better microcirculation because of greater EEP, SHE, and THE.
UR - http://www.scopus.com/inward/record.url?scp=84993734723&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84993734723&partnerID=8YFLogxK
U2 - 10.1177/2150135114526760
DO - 10.1177/2150135114526760
M3 - Article
C2 - 24958048
AN - SCOPUS:84993734723
SN - 2150-1351
VL - 5
SP - 440
EP - 448
JO - World Journal for Pediatric and Congenital Heart Surgery
JF - World Journal for Pediatric and Congenital Heart Surgery
IS - 3
ER -