TY - JOUR
T1 - Infectious complications after pulsatile-flow and continuous-flow left ventricular assist device implantation
AU - Schaffer, Justin M.
AU - Allen, Jeremiah G.
AU - Weiss, Eric S.
AU - Arnaoutakis, George J.
AU - Patel, Nishant D.
AU - Russell, Stuart D.
AU - Shah, Ashish S.
AU - Conte, John V.
N1 - Funding Information:
This work was supported in part by a Ruth L. Kirschstein National Research Service Award ( NIH 2T32DK007713-12 to E.S.W.).
PY - 2011/2
Y1 - 2011/2
N2 - Background Infection is a significant source of morbidity and mortality after left ventricular assist device (LVAD) implantation. Newer generation continuous-flow (CF) LVADs are smaller, requiring smaller pump pockets and drive-line exit sites as compared with pulsatile-flow (PF) devices. With their recent adoption, CF device patients benefit from improved provider experience in the detection and treatment of infectious complications. Given these advances in design and experience, we examined the incidence of infectious complications in patients receiving CF and PF devices. Methods We reviewed patients who received CF or PF LVADs (June 2000 to May 2009) at our institution. Incidences and timing of systemic infections (bacteremia, sepsis, severe sepsis, septic shock), device-associated infections (drive-line, LVAD pocket, sternal wound) and nondevice-associated infections (catheter-related bloodstream, pneumonia, urinary tract) were compared between devices. Primary outcomes were sepsis, severe sepsis, a composite of drive-line and LVAD pocket infection, and catheter-related bloodstream infection. Results Of 133 LVADs, 86 were CF. CF patients had lower pre-operative risk, more recent device implantation, and longer LVAD support time. Device type was highly correlated with reduced infections; however, on multivariate analysis, implantation date appeared to drive this association. KaplanMeier estimates of freedom from all primary outcomes were improved with more recent implantation (p < 0.05). On multivariate analysis, implantation date was predictive of all primary outcomes except severe sepsis, for which advanced age and worse Seattle Heart Failure Model score were predictive. Conclusion In this institutional review of post-LVAD infections, a decrease in infectious complications in CF patients was likely related to increased provider experience associated with a more recent date of implantation.
AB - Background Infection is a significant source of morbidity and mortality after left ventricular assist device (LVAD) implantation. Newer generation continuous-flow (CF) LVADs are smaller, requiring smaller pump pockets and drive-line exit sites as compared with pulsatile-flow (PF) devices. With their recent adoption, CF device patients benefit from improved provider experience in the detection and treatment of infectious complications. Given these advances in design and experience, we examined the incidence of infectious complications in patients receiving CF and PF devices. Methods We reviewed patients who received CF or PF LVADs (June 2000 to May 2009) at our institution. Incidences and timing of systemic infections (bacteremia, sepsis, severe sepsis, septic shock), device-associated infections (drive-line, LVAD pocket, sternal wound) and nondevice-associated infections (catheter-related bloodstream, pneumonia, urinary tract) were compared between devices. Primary outcomes were sepsis, severe sepsis, a composite of drive-line and LVAD pocket infection, and catheter-related bloodstream infection. Results Of 133 LVADs, 86 were CF. CF patients had lower pre-operative risk, more recent device implantation, and longer LVAD support time. Device type was highly correlated with reduced infections; however, on multivariate analysis, implantation date appeared to drive this association. KaplanMeier estimates of freedom from all primary outcomes were improved with more recent implantation (p < 0.05). On multivariate analysis, implantation date was predictive of all primary outcomes except severe sepsis, for which advanced age and worse Seattle Heart Failure Model score were predictive. Conclusion In this institutional review of post-LVAD infections, a decrease in infectious complications in CF patients was likely related to increased provider experience associated with a more recent date of implantation.
UR - http://www.scopus.com/inward/record.url?scp=78650948706&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=78650948706&partnerID=8YFLogxK
U2 - 10.1016/j.healun.2010.08.003
DO - 10.1016/j.healun.2010.08.003
M3 - Article
C2 - 20888258
AN - SCOPUS:78650948706
SN - 1053-2498
VL - 30
SP - 164
EP - 174
JO - Journal of Heart and Lung Transplantation
JF - Journal of Heart and Lung Transplantation
IS - 2
ER -