TY - JOUR
T1 - Influence of High Total Dissolved Solids Concentration and Ionic Composition on γspectroscopy Radium Measurements of Oil and Gas-Produced Water
AU - Ajemigbitse, Moses A.
AU - Tasker, Travis L.
AU - Cannon, Fred S.
AU - Warner, Nathaniel R.
N1 - Publisher Copyright:
© 2019 American Chemical Society.
PY - 2019/9/3
Y1 - 2019/9/3
N2 - Radium measurements in high total dissolved solids (TDS) fluids from oil and gas extraction can have unfavorable precision and accuracy, in part because these high-level impurities incur attenuation. γspectroscopy is often recommended for determining radium activities in these fluids, but even this method can produce a range of reported activities for the same sample. To reduce measurement duration and to maintain or improve accuracy, we propose a method to rapidly assess both 226Ra and 228Ra and to account for the self-attenuation of γrays in high-TDS oil and gas fluids when they are monitored by a well detector. In this work, comparisons between a NaCl-only and a multi-cation-chloride synthetic brine spiked with known amounts of 226Ra and 228Ra indicated that both the TDS concentration and the type of TDS (i.e., Na only vs Na-Mg-Ba-Ca-Sr) influenced self-attenuation in well-detector γspectroscopy, thus highlighting the need to correct for this TDS-influenced self-attenuation. Radium activities can be underestimated if the correction is not applied. For instance, 226Ra activities could be â¼40% lower in a sample when measured directly at the 186 keV energy level if the attenuation of the high TDS of the fluid is not considered. We also showed that using a NaCl-only brine to match the matrix of high-TDS oil and gas brines is inadequate to produce accurate measurements, rather, the full set of cations should be included.
AB - Radium measurements in high total dissolved solids (TDS) fluids from oil and gas extraction can have unfavorable precision and accuracy, in part because these high-level impurities incur attenuation. γspectroscopy is often recommended for determining radium activities in these fluids, but even this method can produce a range of reported activities for the same sample. To reduce measurement duration and to maintain or improve accuracy, we propose a method to rapidly assess both 226Ra and 228Ra and to account for the self-attenuation of γrays in high-TDS oil and gas fluids when they are monitored by a well detector. In this work, comparisons between a NaCl-only and a multi-cation-chloride synthetic brine spiked with known amounts of 226Ra and 228Ra indicated that both the TDS concentration and the type of TDS (i.e., Na only vs Na-Mg-Ba-Ca-Sr) influenced self-attenuation in well-detector γspectroscopy, thus highlighting the need to correct for this TDS-influenced self-attenuation. Radium activities can be underestimated if the correction is not applied. For instance, 226Ra activities could be â¼40% lower in a sample when measured directly at the 186 keV energy level if the attenuation of the high TDS of the fluid is not considered. We also showed that using a NaCl-only brine to match the matrix of high-TDS oil and gas brines is inadequate to produce accurate measurements, rather, the full set of cations should be included.
UR - http://www.scopus.com/inward/record.url?scp=85071788801&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85071788801&partnerID=8YFLogxK
U2 - 10.1021/acs.est.9b03035
DO - 10.1021/acs.est.9b03035
M3 - Article
C2 - 31429285
AN - SCOPUS:85071788801
SN - 0013-936X
VL - 53
SP - 10295
EP - 10302
JO - Environmental Science and Technology
JF - Environmental Science and Technology
IS - 17
ER -