T1 - Interaction between phase shifting transformers installed in the tie-lines of interconnected power systems and automatic frequency controllers
AU - Rasolomampionona, Desire
AU - Anwar, Sohail
N1 - Funding Information:
In this paper, some results of a research financed by the Polish SCSR (State Committee for Scientific Research) are presented. The problem concerning the coordination of the FACTS devices like TCPAR, used for tie-line power control in interconnected power systems equipped with AGC is presented in this paper.
Copyright:
Copyright 2011 Elsevier B.V., All rights reserved.
PY - 2011/10
Y1 - 2011/10
N2 - FACTS devices like TCPAR can be used to regulate the power flow in tie-lines of interconnected power system. The transient state power flow occurring after power disturbances can be influenced by using TCPAR equipped with power regulator and frequency-based stabilizer. The analysis of a simple interconnected power system consisting of two power systems has shown that the control of TCPAR can force a good damping of both power swings and oscillations of local frequency. In the case of a larger interconnected power system consisting of more than two power systems, the influence of the control of TCPAR on damping can be more complicated. Strong damping of local frequency oscillations and power swings in one tie-line may cause larger oscillations in remote tie-lines and other systems. Hence the use of devices like TCPAR as tools for damping power swings and frequency oscillations in a large interconnected power system must be justified by detailed analysis of power system dynamics. In this paper, some results of time-domain simulations of a three-system area are presented. These results have proven that it is possible to obtain a good damping of tie-line power and frequency swings by optimizing the main parameters of TCPAR installed in tie-lines. The results have been confirmed by an eigenvalue analysis of linearized model of interconnected system consisting of three subsystems.
AB - FACTS devices like TCPAR can be used to regulate the power flow in tie-lines of interconnected power system. The transient state power flow occurring after power disturbances can be influenced by using TCPAR equipped with power regulator and frequency-based stabilizer. The analysis of a simple interconnected power system consisting of two power systems has shown that the control of TCPAR can force a good damping of both power swings and oscillations of local frequency. In the case of a larger interconnected power system consisting of more than two power systems, the influence of the control of TCPAR on damping can be more complicated. Strong damping of local frequency oscillations and power swings in one tie-line may cause larger oscillations in remote tie-lines and other systems. Hence the use of devices like TCPAR as tools for damping power swings and frequency oscillations in a large interconnected power system must be justified by detailed analysis of power system dynamics. In this paper, some results of time-domain simulations of a three-system area are presented. These results have proven that it is possible to obtain a good damping of tie-line power and frequency swings by optimizing the main parameters of TCPAR installed in tie-lines. The results have been confirmed by an eigenvalue analysis of linearized model of interconnected system consisting of three subsystems.
UR - http://www.scopus.com/inward/record.url?scp=80051548333&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=80051548333&partnerID=8YFLogxK
U2 - 10.1016/j.ijepes.2011.06.001
DO - 10.1016/j.ijepes.2011.06.001
M3 - Article
AN - SCOPUS:80051548333
SN - 0142-0615
VL - 33
SP - 1351
EP - 1360
JO - International Journal of Electrical Power and Energy Systems
JF - International Journal of Electrical Power and Energy Systems
IS - 8
ER -