TY - JOUR
T1 - Long-Term Suppression of Atrial Fibrillation by Botulinum Toxin Injection into Epicardial Fat Pads in Patients Undergoing Cardiac Surgery
T2 - One-Year Follow-Up of a Randomized Pilot Study
AU - Pokushalov, Evgeny
AU - Kozlov, Boris
AU - Romanov, Alexander
AU - Strelnikov, Artem
AU - Bayramova, Sevda
AU - Sergeevichev, David
AU - Bogachev-Prokophiev, Alexander
AU - Zheleznev, Sergey
AU - Shipulin, Vladimir
AU - Lomivorotov, Vladimir V.
AU - Karaskov, Alexander
AU - Po, Sunny S.
AU - Steinberg, Jonathan S.
N1 - Publisher Copyright:
© 2015 American Heart Association, Inc.
PY - 2015/12/1
Y1 - 2015/12/1
N2 - Animal models suggest that the neurotransmitter inhibitor, botulinum toxin, when injected into the epicardial fat pads can suppress atrial fibrillation inducibility. The aim of this prospective randomized double-blind study was to compare the efficacy and safety of botulinum toxin injection into epicardial fat pads for preventing atrial tachyarrhythmias. Methods and Results-Patients with history of paroxysmal atrial fibrillation and indication for coronary artery bypass graft surgery were randomized to botulinum toxin (Xeomin, Merz, Germany; 50 U/1 mL at each fat pad; n=30) or placebo (0.9% normal saline, 1 mL at each fat pad; n=30) injection into epicardial fat pads during surgery. Patients were followed for 1 year to assess maintenance of sinus rhythm using an implantable loop recorder. All patients in both groups had successful epicardial fat pad injections without complications. The incidence of early postoperative atrial fibrillation within 30 days after coronary artery bypass graft was 2 of 30 patients (7%) in the botulinum toxin group and 9 of 30 patients (30%) in the placebo group (P=0.024). Between 30 days and up to the 12-month follow-up examination, 7 of the 30 patients in the placebo group (27%) and none of the 30 patients in the botulinum toxin group (0%) had recurrent atrial fibrillation (P=0.002). There were no complications observed during the 1-year follow-up. Conclusions-Botulinum toxin injection into epicardial fat pads during coronary artery bypass graft provided substantial atrial tachyarrhythmia suppression both early as well as during 1-year follow-up, without any serious adverse events.
AB - Animal models suggest that the neurotransmitter inhibitor, botulinum toxin, when injected into the epicardial fat pads can suppress atrial fibrillation inducibility. The aim of this prospective randomized double-blind study was to compare the efficacy and safety of botulinum toxin injection into epicardial fat pads for preventing atrial tachyarrhythmias. Methods and Results-Patients with history of paroxysmal atrial fibrillation and indication for coronary artery bypass graft surgery were randomized to botulinum toxin (Xeomin, Merz, Germany; 50 U/1 mL at each fat pad; n=30) or placebo (0.9% normal saline, 1 mL at each fat pad; n=30) injection into epicardial fat pads during surgery. Patients were followed for 1 year to assess maintenance of sinus rhythm using an implantable loop recorder. All patients in both groups had successful epicardial fat pad injections without complications. The incidence of early postoperative atrial fibrillation within 30 days after coronary artery bypass graft was 2 of 30 patients (7%) in the botulinum toxin group and 9 of 30 patients (30%) in the placebo group (P=0.024). Between 30 days and up to the 12-month follow-up examination, 7 of the 30 patients in the placebo group (27%) and none of the 30 patients in the botulinum toxin group (0%) had recurrent atrial fibrillation (P=0.002). There were no complications observed during the 1-year follow-up. Conclusions-Botulinum toxin injection into epicardial fat pads during coronary artery bypass graft provided substantial atrial tachyarrhythmia suppression both early as well as during 1-year follow-up, without any serious adverse events.
UR - https://www.scopus.com/pages/publications/84950105984
UR - https://www.scopus.com/inward/citedby.url?scp=84950105984&partnerID=8YFLogxK
U2 - 10.1161/CIRCEP.115.003199
DO - 10.1161/CIRCEP.115.003199
M3 - Article
C2 - 26486855
AN - SCOPUS:84950105984
SN - 1941-3149
VL - 8
SP - 1334
EP - 1341
JO - Circulation: Arrhythmia and Electrophysiology
JF - Circulation: Arrhythmia and Electrophysiology
IS - 6
ER -