TY - JOUR
T1 - Low-Cost Scalable PCB-Based 2-D Transducer Arrays for Volumetric Photoacoustic Imaging
AU - Mitra, Mahaan
AU - Kumar, Akshay
AU - Khandare, Shubham
AU - Gaddale, Prameth
AU - Anandan, Yashoda
AU - Pedibhotla, Srian
AU - Roy, Kaustav
AU - Chen, Haoyang
AU - Pratap, Rudra
AU - Kothapalli, Sri Rajasekhar
N1 - Publisher Copyright:
© 2001-2012 IEEE.
PY - 2024/2/15
Y1 - 2024/2/15
N2 - Photoacoustic (PA) imaging provides deep tissue molecular imaging of chromophores with optical absorption contrast and ultrasonic resolution. Present PA imaging techniques are predominantly limited to one 2-D plane per acquisition. The 2-D ultrasound (US) transducers, required for real-time 3-D PA imaging, are high cost, complex to fabricate, and have limited scalability in design. We present novel printed circuit board (PCB)-based 2-D matrix US transducer arrays that are capable of being bulk manufactured at low cost without using laborious US fabrication tools. The 2-D US array specifications are easily scalable with respect to widely available PCB design tools. To demonstrate scalability, we fabricated low-frequency (11 MHz) $8\times8$ matrix array and high-frequency (40 MHz) $4\times4$ matrix array by directly bonding an undiced polyvinylidene difluoride (PVDF) piezoelectric material of desired thickness to the custom designed PCB substrate. Characterization results demonstrate wideband PA receive sensitivity for both the low-frequency (6-dB bandwidth: 87%) and the high-frequency (6-dB bandwidth: 188%) arrays. Volumetric PA imaging results of light-absorbing targets inside optical scattering medium demonstrate improved spatial resolution and field of view (FOV) with an increase in aperture size.
AB - Photoacoustic (PA) imaging provides deep tissue molecular imaging of chromophores with optical absorption contrast and ultrasonic resolution. Present PA imaging techniques are predominantly limited to one 2-D plane per acquisition. The 2-D ultrasound (US) transducers, required for real-time 3-D PA imaging, are high cost, complex to fabricate, and have limited scalability in design. We present novel printed circuit board (PCB)-based 2-D matrix US transducer arrays that are capable of being bulk manufactured at low cost without using laborious US fabrication tools. The 2-D US array specifications are easily scalable with respect to widely available PCB design tools. To demonstrate scalability, we fabricated low-frequency (11 MHz) $8\times8$ matrix array and high-frequency (40 MHz) $4\times4$ matrix array by directly bonding an undiced polyvinylidene difluoride (PVDF) piezoelectric material of desired thickness to the custom designed PCB substrate. Characterization results demonstrate wideband PA receive sensitivity for both the low-frequency (6-dB bandwidth: 87%) and the high-frequency (6-dB bandwidth: 188%) arrays. Volumetric PA imaging results of light-absorbing targets inside optical scattering medium demonstrate improved spatial resolution and field of view (FOV) with an increase in aperture size.
UR - http://www.scopus.com/inward/record.url?scp=85181577269&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85181577269&partnerID=8YFLogxK
U2 - 10.1109/JSEN.2023.3344824
DO - 10.1109/JSEN.2023.3344824
M3 - Article
C2 - 38505656
AN - SCOPUS:85181577269
SN - 1530-437X
VL - 24
SP - 4380
EP - 4386
JO - IEEE Sensors Journal
JF - IEEE Sensors Journal
IS - 4
ER -