TY - JOUR
T1 - Lung volume reduction surgery restores the normal diaphragmatic length-tension relationship in emphysematous rats
AU - Shrager, Joseph B.
AU - Kim, Dong Kwan
AU - Hashmi, Yahya J.
AU - Lankford, Edward B.
AU - Wahl, Peter
AU - Stedman, Hansell H.
AU - Levine, Sanford
AU - Kaiser, Larry R.
N1 - Funding Information:
Supported by research grants to J.B.S. from the Veterans Affairs Stars and Stripes Healthcare Network and the American Association for Thoracic Surgery. J.B.S. is a recipient of the Churchill Research Scholarship of The American Association for Thoracic Surgery.
PY - 2001
Y1 - 2001
N2 - Objective: Improved respiratory muscle function is a major effect of a lung volume reduction surgery. We studied length adaptation in rat diaphragmatic muscle in an attempt to elucidate the mechanism by which diaphragmatic function improves after this controversial operation. Methods: We developed a model of elastase-induced emphysema and bilateral volume reduction through median sternotomy in rats. Five months after emphysema induction, maximum exchangeable lung volume was determined in intubated and anesthetized control animals and animals with emphysema. Costal diaphragmatic length was measured in vivo, and the length at which maximal twitch force is generated was determined on muscle strips in vitro. Also 5 months after elastase administration, another cohort underwent volume reduction or sham sternotomy. Five months after the operation, these animals were similarly studied. Results: Lung volume was increased in emphysematous rats versus control rats (50.9 ± 1.7 vs 45.4 ± 1.3 mL, P = .001). Lung volume was decreased in emphysematous animals that had undergone volume reduction versus sham sternotomy (44.7 ± 0.60 vs 49.4 ± 1.0 mL, P = .001). In situ diaphragm length (1.99 ± 0.04 vs 2.24 ± 0.07 cm, P = .001) and the length at which maximal twitch force is generated (2.25 ± 0.06 vs 2.48 ± 0.09 cm, P = .038) were shorter in emphysematous than control animals. After volume reduction, in situ diaphragm length (2.13 ± 0.06 vs 1.83 ± 0.02 cm, P < .001) and the length at which maximal twitch force is generated (2.50 ± 0.08 vs 2.27 ± 0.06 cm, P = .013) were longer than in animals undergoing sham sternotomy. Conclusions: In this experimental model of emphysema and lung volume reduction surgery, emphysema shortens the length at which maximal twitch force is generated and shifts the diaphragmatic length-tension curve to lower lengths; volume reduction returns the length at which maximal twitch force is generated toward normal and shifts the diaphragmatic length-tension curve back to longer lengths. This restoration toward normal physiology may enable the improvement in diaphragmatic function seen after lung volume reduction surgery. The mechanism by which these length adaptations occur merits further investigation.
AB - Objective: Improved respiratory muscle function is a major effect of a lung volume reduction surgery. We studied length adaptation in rat diaphragmatic muscle in an attempt to elucidate the mechanism by which diaphragmatic function improves after this controversial operation. Methods: We developed a model of elastase-induced emphysema and bilateral volume reduction through median sternotomy in rats. Five months after emphysema induction, maximum exchangeable lung volume was determined in intubated and anesthetized control animals and animals with emphysema. Costal diaphragmatic length was measured in vivo, and the length at which maximal twitch force is generated was determined on muscle strips in vitro. Also 5 months after elastase administration, another cohort underwent volume reduction or sham sternotomy. Five months after the operation, these animals were similarly studied. Results: Lung volume was increased in emphysematous rats versus control rats (50.9 ± 1.7 vs 45.4 ± 1.3 mL, P = .001). Lung volume was decreased in emphysematous animals that had undergone volume reduction versus sham sternotomy (44.7 ± 0.60 vs 49.4 ± 1.0 mL, P = .001). In situ diaphragm length (1.99 ± 0.04 vs 2.24 ± 0.07 cm, P = .001) and the length at which maximal twitch force is generated (2.25 ± 0.06 vs 2.48 ± 0.09 cm, P = .038) were shorter in emphysematous than control animals. After volume reduction, in situ diaphragm length (2.13 ± 0.06 vs 1.83 ± 0.02 cm, P < .001) and the length at which maximal twitch force is generated (2.50 ± 0.08 vs 2.27 ± 0.06 cm, P = .013) were longer than in animals undergoing sham sternotomy. Conclusions: In this experimental model of emphysema and lung volume reduction surgery, emphysema shortens the length at which maximal twitch force is generated and shifts the diaphragmatic length-tension curve to lower lengths; volume reduction returns the length at which maximal twitch force is generated toward normal and shifts the diaphragmatic length-tension curve back to longer lengths. This restoration toward normal physiology may enable the improvement in diaphragmatic function seen after lung volume reduction surgery. The mechanism by which these length adaptations occur merits further investigation.
UR - http://www.scopus.com/inward/record.url?scp=0035134271&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0035134271&partnerID=8YFLogxK
U2 - 10.1067/mtc.2001.111208
DO - 10.1067/mtc.2001.111208
M3 - Article
C2 - 11174726
AN - SCOPUS:0035134271
SN - 0022-5223
VL - 121
SP - 217
EP - 224
JO - Journal of Thoracic and Cardiovascular Surgery
JF - Journal of Thoracic and Cardiovascular Surgery
IS - 2
ER -