AU - Flaska, Marek
AU - Pozzi, Sara A.
PY - 2007
Y1 - 2007
N2 - Accurate identification of radioactive materials is essential in areas such as nuclear nonproliferation, international safeguards, nuclear material control and accountability, and national security. Recently, a new application of a technique that acquires neutron pulse-height spectra using a liquid scintillation detector, a digitizer, and an optimized pulse shape discrimination technique was proposed. The method can be used for accurate identification of neutron sources such as Cf-252, Am-Be, and Am-Li. AU these sources were investigated in combination with several shielding blocks made of polyethylene and lead. From the results it is apparent that source identification is possible by the data inspection of the measured pulse-height distributions. The general slope of the distributions can be used for the source identification, and all sources tested can be accurately identified. All measured pulse-height distributions were also compared to distributions simulated with the MCNP-PoliMi code and very good agreement was achieved.
AB - Accurate identification of radioactive materials is essential in areas such as nuclear nonproliferation, international safeguards, nuclear material control and accountability, and national security. Recently, a new application of a technique that acquires neutron pulse-height spectra using a liquid scintillation detector, a digitizer, and an optimized pulse shape discrimination technique was proposed. The method can be used for accurate identification of neutron sources such as Cf-252, Am-Be, and Am-Li. AU these sources were investigated in combination with several shielding blocks made of polyethylene and lead. From the results it is apparent that source identification is possible by the data inspection of the measured pulse-height distributions. The general slope of the distributions can be used for the source identification, and all sources tested can be accurately identified. All measured pulse-height distributions were also compared to distributions simulated with the MCNP-PoliMi code and very good agreement was achieved.
UR - http://www.scopus.com/inward/record.url?scp=48349101037&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=48349101037&partnerID=8YFLogxK
U2 - 10.1109/NSSMIC.2007.4436315
DO - 10.1109/NSSMIC.2007.4436315
M3 - Conference contribution
AN - SCOPUS:48349101037
SN - 1424409233
SN - 9781424409235
T3 - IEEE Nuclear Science Symposium Conference Record
SP - 199
EP - 203
BT - 2007 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS-MIC
T2 - 2007 IEEE Nuclear Science Symposium and Medical Imaging Conference, NSS-MIC
Y2 - 27 October 2007 through 3 November 2007
ER -