T1 - Membrane-coated electrochemical probe for corrosion measurements of high strength carbon steel in supercritical CO2
AU - Beck, Justin
AU - Fedkin, Mark
AU - Lvov, Serguei
AU - Ziomek-Moroz, Margaret
PY - 2013
Y1 - 2013
N2 - Growing interest in transporting supercritical carbon dioxide (scCO2) for enhanced oil recovery and carbon capture and storage has led to an increased interest in the corrosion behavior of pipeline steels in scCO2 fluids with varying levels of water contamination. Electrochemical measurements in scCO2 fluids have been limited by the very low solution conductivity, even in fluids saturated with water vapor. Electrochemical corrosion measurements using linear polarization resistance, electrochemical impedance spectroscopy, and electrochemical frequency modulation are presented here for X65 carbon steel in supercritical carbon dioxide contaminated with water vapor. The low solution conductivity was overcome using a coating of ion conducting polymer over the corrosion probe. The results showed that increasing membrane thickness resulted in reductions to both charge transfer and mass transfer rates. It is proposed here that this behavior was a result of the thickness of the aqueous film varying with the membrane thickness. Improving the process of applying the membrane could allow electrochemical corrosion measurements to be performed in low-conductivity environments with respect to varying thicknesses of the aqueous film.
AB - Growing interest in transporting supercritical carbon dioxide (scCO2) for enhanced oil recovery and carbon capture and storage has led to an increased interest in the corrosion behavior of pipeline steels in scCO2 fluids with varying levels of water contamination. Electrochemical measurements in scCO2 fluids have been limited by the very low solution conductivity, even in fluids saturated with water vapor. Electrochemical corrosion measurements using linear polarization resistance, electrochemical impedance spectroscopy, and electrochemical frequency modulation are presented here for X65 carbon steel in supercritical carbon dioxide contaminated with water vapor. The low solution conductivity was overcome using a coating of ion conducting polymer over the corrosion probe. The results showed that increasing membrane thickness resulted in reductions to both charge transfer and mass transfer rates. It is proposed here that this behavior was a result of the thickness of the aqueous film varying with the membrane thickness. Improving the process of applying the membrane could allow electrochemical corrosion measurements to be performed in low-conductivity environments with respect to varying thicknesses of the aqueous film.
UR - http://www.scopus.com/inward/record.url?scp=84883869573&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84883869573&partnerID=8YFLogxK
M3 - Conference contribution
AN - SCOPUS:84883869573
SN - 9781627481458
T3 - NACE - International Corrosion Conference Series
BT - NACE International - Corrosion 2013 Conference and Expo
T2 - Corrosion 2013
Y2 - 17 March 2013 through 21 March 2013
ER -