T1 - Micro coulter counters with platinum black electroplated electrodes for human blood cell sensing
AU - Zheng, Siyang
AU - Liu, Mike
AU - Tai, Yu Chong
N1 - Funding Information:
Acknowledgement This work is supported by the National Space Biomedical Research Institute through NASA NCC 9–58. The authors would like to thank other members of the Caltech Micromachining Laboratory for their valuable assistance.
PY - 2008/4
Y1 - 2008/4
N2 - We demonstrated a novel micro Coulter counter featuring platinum-black electrodes for human blood cell counting application. Two designs of micro Coulter counter were fabricated using two distinct technologies: integrated parylene and soft lithography. Platinum-black enhanced detection in the intermediate frequency range (∼100 Hz to 7 MHz), which is the operation frequency suitable for sensing the cells flowing by the electrodes. A detailed theoretical modeling of the sensing mechanism has been performed for the design of the electrodes, and electrical impedance spectra measurements confirmed the theoretical model. The surface morphology and roughness of the platinum black electroplated surface were characterized by SEM and AFM measurements. Polystyrene beads of various sizes were initially used to validate the operation of the devices, and using excitation frequency of 10 kHz, the signal magnitude was found to be correlated with the volume of the individual bead. Human blood cell sensing was successfully demonstrated with diluted whole blood and leukocyte rich plasma under the same excitation frequency. The histogram of impedance magnitude of the cells matched well with volume distributions of erythrocytes and leukocytes measured by conventional counting techniques. Micro Coulter counters have the advantages of small foot-print, low sample volume, and reduced cost of operation. Further development of the devices can lead to the development of a highly-sensitive and high-throughput handheld blood counting system for point-of-care applications.
AB - We demonstrated a novel micro Coulter counter featuring platinum-black electrodes for human blood cell counting application. Two designs of micro Coulter counter were fabricated using two distinct technologies: integrated parylene and soft lithography. Platinum-black enhanced detection in the intermediate frequency range (∼100 Hz to 7 MHz), which is the operation frequency suitable for sensing the cells flowing by the electrodes. A detailed theoretical modeling of the sensing mechanism has been performed for the design of the electrodes, and electrical impedance spectra measurements confirmed the theoretical model. The surface morphology and roughness of the platinum black electroplated surface were characterized by SEM and AFM measurements. Polystyrene beads of various sizes were initially used to validate the operation of the devices, and using excitation frequency of 10 kHz, the signal magnitude was found to be correlated with the volume of the individual bead. Human blood cell sensing was successfully demonstrated with diluted whole blood and leukocyte rich plasma under the same excitation frequency. The histogram of impedance magnitude of the cells matched well with volume distributions of erythrocytes and leukocytes measured by conventional counting techniques. Micro Coulter counters have the advantages of small foot-print, low sample volume, and reduced cost of operation. Further development of the devices can lead to the development of a highly-sensitive and high-throughput handheld blood counting system for point-of-care applications.
UR - http://www.scopus.com/inward/record.url?scp=40349099998&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=40349099998&partnerID=8YFLogxK
U2 - 10.1007/s10544-007-9128-5
DO - 10.1007/s10544-007-9128-5
M3 - Article
C2 - 17876707
AN - SCOPUS:40349099998
SN - 1387-2176
VL - 10
SP - 221
EP - 231
JO - Biomedical Microdevices
JF - Biomedical Microdevices
IS - 2
ER -