Abstract
A falling-film milk pasteurizer-sterilizer was used to process milk at temperatures from 126.7 C to 148.9 C at a fixed holding time of 1.79 s. Processed milks were dispensed in 10 ml and 4 liter volumes and stored at 28 and 32 C for up to 10 wk. At processing temperatures in excess of 137.8 C, the milk was microbiologically stable during storage.
Original language | English (US) |
---|---|
Pages (from-to) | 1003-1009 |
Number of pages | 7 |
Journal | Journal of Dairy Science |
Volume | 59 |
Issue number | 6 |
DOIs | |
State | Published - 1976 |
All Science Journal Classification (ASJC) codes
- Food Science
- Animal Science and Zoology
- Genetics