TY - JOUR
T1 - Mini-aortic valve replacements are not associated with an increased incidence of patient–prosthesis mismatch
T2 - a propensity-scored analysis
AU - Magruder, J. Trent
AU - Grimm, Joshua C.
AU - Kilic, Arman
AU - Crawford, Todd
AU - Conte, John
AU - Cameron, Duke E.
AU - Shah, Ashish S.
PY - 2016/3/1
Y1 - 2016/3/1
N2 - Objectives: We sought to determine whether an AVR performed though a partial upper hemisternotomy (“mini-AVR”) resulted in a greater incidence of patient–prosthesis mismatch (PPM) than those through a full median sternotomy (“AVR”). Methods: Patients undergoing isolated aortic valve replacement from 2008 to 2013 were identified. Moderate PPM was defined as an in vivo effective orifice area ≤0.85 cm2/m2 body surface area; severe PPM was defined as ≤0.65 cm2/m2. A propensity score-matched analysis was utilized to compare the incidence of PPM between these groups. Results: Of the 630 patients undergoing aortic valve surgery, 90 (14.3 %) received mini-AVRs and 540 (85.7 %) received regular AVRs. After propensity matching, we established two cohorts of 85 patients receiving each procedure. Both cohorts were similar with regard to all preoperative covariates including mean age (65.5 vs. 65.1, p = 0.85), diabetes (17.7 vs. 22.4 %), mean BMI (28.3 vs. 28.6, p = 0.73), mean EF (56.9 vs. 55.6, p = 0.43), proportion of patients with aortic stenosis (70.6 vs. 71.8 %, p = 1.00), preoperative valve area (0.88 vs. 0.93 cm2, p = 0.67), and proportion who received a bioprosthesis (85.9 vs. 83.5 %, p = 0.59). Postoperatively, 27.4 % of mini-AVRs and 26.8 % of AVRs had moderate PPM (p = 0.93); 2.4 and 1.2 % had severe PPM (p = 0.66). Kaplan–Meier analysis also failed to reveal a difference in 1-year survival between mini and regular AVRs (93.7 vs. 90.5 %, p = 0.49). Conclusions: After propensity matching, mini-AVRs are not associated with a greater incidence of PPM than regular AVRs. Severe PPM was rare across both procedure types in this surgical series.
AB - Objectives: We sought to determine whether an AVR performed though a partial upper hemisternotomy (“mini-AVR”) resulted in a greater incidence of patient–prosthesis mismatch (PPM) than those through a full median sternotomy (“AVR”). Methods: Patients undergoing isolated aortic valve replacement from 2008 to 2013 were identified. Moderate PPM was defined as an in vivo effective orifice area ≤0.85 cm2/m2 body surface area; severe PPM was defined as ≤0.65 cm2/m2. A propensity score-matched analysis was utilized to compare the incidence of PPM between these groups. Results: Of the 630 patients undergoing aortic valve surgery, 90 (14.3 %) received mini-AVRs and 540 (85.7 %) received regular AVRs. After propensity matching, we established two cohorts of 85 patients receiving each procedure. Both cohorts were similar with regard to all preoperative covariates including mean age (65.5 vs. 65.1, p = 0.85), diabetes (17.7 vs. 22.4 %), mean BMI (28.3 vs. 28.6, p = 0.73), mean EF (56.9 vs. 55.6, p = 0.43), proportion of patients with aortic stenosis (70.6 vs. 71.8 %, p = 1.00), preoperative valve area (0.88 vs. 0.93 cm2, p = 0.67), and proportion who received a bioprosthesis (85.9 vs. 83.5 %, p = 0.59). Postoperatively, 27.4 % of mini-AVRs and 26.8 % of AVRs had moderate PPM (p = 0.93); 2.4 and 1.2 % had severe PPM (p = 0.66). Kaplan–Meier analysis also failed to reveal a difference in 1-year survival between mini and regular AVRs (93.7 vs. 90.5 %, p = 0.49). Conclusions: After propensity matching, mini-AVRs are not associated with a greater incidence of PPM than regular AVRs. Severe PPM was rare across both procedure types in this surgical series.
UR - http://www.scopus.com/inward/record.url?scp=84959336476&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84959336476&partnerID=8YFLogxK
U2 - 10.1007/s11748-015-0614-z
DO - 10.1007/s11748-015-0614-z
M3 - Article
C2 - 26688505
AN - SCOPUS:84959336476
SN - 1863-6705
VL - 64
SP - 144
EP - 148
JO - General Thoracic and Cardiovascular Surgery
JF - General Thoracic and Cardiovascular Surgery
IS - 3
ER -