Modelling study of disinfection and contaminant formation associated with far-UVC light (222 nm)

Seongjun Park, Donghyun Rim

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

This study investigates the disinfection and formation of air contaminants associated with two types of far-UVC light (ceiling-mounted and standing) in an office room. The ceiling-mounted type yields 20 - 30% better disinfection performance than the standing type. However, a marginal difference was observed for the concentration of secondary organic aerosols (SOA) within the breathing zone.

Original languageEnglish (US)
Title of host publication18th Conference of the International Society of Indoor Air Quality and Climate, INDOOR AIR 2024 - Conference Program and Proceedings
PublisherInternational Society of Indoor Air Quality and Climate
ISBN (Electronic)9798331306816
StatePublished - 2024
Event18th International Conference on Indoor Air Quality and Climate, INDOOR AIR 2024 - Honolulu, United States
Duration: Jul 7 2024Jul 11 2024

Publication series

Name18th Conference of the International Society of Indoor Air Quality and Climate, INDOOR AIR 2024 - Conference Program and Proceedings

Conference

Conference18th International Conference on Indoor Air Quality and Climate, INDOOR AIR 2024
Country/TerritoryUnited States
CityHonolulu
Period7/7/247/11/24