TY - JOUR
T1 - Monitoring a bioprocess for ethanol production using FT-MIR and FT-Raman spectroscopy
AU - Sivakesava, S.
AU - Irudayaraj, J.
AU - Demirci, A.
N1 - Copyright:
Copyright 2007 Elsevier B.V., All rights reserved.
PY - 2001
Y1 - 2001
N2 - The application of Fourier transform mid-infrared (FT-MIR) spectroscopy and Fourier transform Raman (FT-Raman) spectroscopy for process and quality control of fermentative production of ethanol was investigated. FT-MIR and FT-Raman spectroscopy along with multivariate techniques were used to determine simultaneously glucose, ethanol, and optical cell density of Saccharomyces cerevisiae during ethanol fermentation. Spectroscopic measurement of glucose and ethanol were compared and validated with the high-performance liquid chromatography (HPLC) method. Spectral wave number regions were selected for partial least-squares (PLS) regression and principal component regression (PCR) and calibration models for glucose, ethanol, and optical cell density were developed for culture samples. Correlation coefficient (R2) value for the prediction for glucose and ethanol was more than 0.9 using various calibration methods. The standard error of prediction for the PLS first-derivative calibration models for glucose, ethanol, and optical cell density were 1.938 g/l, 1.150 g/l, and 0.507, respectively. Prediction errors were high with FT-Raman because the Raman scattering of the cultures was weak. Results indicated that FT-MIR spectroscopy could be used for rapid detection of glucose, ethanol, and optical cell density in S. cerevisiae culture during ethanol fermentation.
AB - The application of Fourier transform mid-infrared (FT-MIR) spectroscopy and Fourier transform Raman (FT-Raman) spectroscopy for process and quality control of fermentative production of ethanol was investigated. FT-MIR and FT-Raman spectroscopy along with multivariate techniques were used to determine simultaneously glucose, ethanol, and optical cell density of Saccharomyces cerevisiae during ethanol fermentation. Spectroscopic measurement of glucose and ethanol were compared and validated with the high-performance liquid chromatography (HPLC) method. Spectral wave number regions were selected for partial least-squares (PLS) regression and principal component regression (PCR) and calibration models for glucose, ethanol, and optical cell density were developed for culture samples. Correlation coefficient (R2) value for the prediction for glucose and ethanol was more than 0.9 using various calibration methods. The standard error of prediction for the PLS first-derivative calibration models for glucose, ethanol, and optical cell density were 1.938 g/l, 1.150 g/l, and 0.507, respectively. Prediction errors were high with FT-Raman because the Raman scattering of the cultures was weak. Results indicated that FT-MIR spectroscopy could be used for rapid detection of glucose, ethanol, and optical cell density in S. cerevisiae culture during ethanol fermentation.
UR - http://www.scopus.com/inward/record.url?scp=0034914239&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0034914239&partnerID=8YFLogxK
U2 - 10.1038/sj.jim.7000124
DO - 10.1038/sj.jim.7000124
M3 - Article
C2 - 11464265
AN - SCOPUS:0034914239
SN - 1367-5435
VL - 26
SP - 185
EP - 190
JO - Journal of Industrial Microbiology and Biotechnology
JF - Journal of Industrial Microbiology and Biotechnology
IS - 4
ER -