TY - JOUR
T1 - Multi-modality cerebral aneurysm haemodynamic analysis
T2 - In vivo 4D flow MRI, in vitro volumetric particle velocimetry and in silico computational fluid dynamics
AU - Brindise, Melissa C.
AU - Rothenberger, Sean
AU - Dickerhoff, Benjamin
AU - Schnell, Susanne
AU - Markl, Michael
AU - Saloner, David
AU - Rayz, Vitaliy L.
AU - Vlachos, Pavlos P.
N1 - Publisher Copyright:
© 2019 The Author(s) Published by the Royal Society. All rights reserved.
PY - 2019
Y1 - 2019
N2 - Typical approaches to patient-specific haemodynamic studies of cerebral aneurysms use image-based computational fluid dynamics (CFD) and seek to statistically correlate parameters such as wall shear stress (WSS) and oscillatory shear index (OSI) to risk of growth and rupture. However, such studies have reported contradictory results, emphasizing the need for in-depth multi-modality haemodynamic metric evaluation. In this work, we used in vivo 4D flow MRI data to inform in vitro particle velocimetry and CFD modalities in two patient-specific cerebral aneurysm models (basilar tip and internal carotid artery). Pulsatile volumetric particle velocimetry experiments were conducted, and the particle images were processed using Shake-the-Box, a particle tracking method. Distributions of normalized WSS and relative residence time were shown to be highly yet inconsistently affected by minor flow field and spatial resolution variations across modalities, and specific relationships among these should be explored in future work. Conversely, OSI, a non-dimensional parameter, was shown to be more robust to the varying assumptions, limitations and spatial resolutions of each subject and modality. These results suggest a need for further multi-modality analysis as well as development of non-dimensional haemodynamic parameters and correlation of such metrics to aneurysm risk of growth and rupture.
AB - Typical approaches to patient-specific haemodynamic studies of cerebral aneurysms use image-based computational fluid dynamics (CFD) and seek to statistically correlate parameters such as wall shear stress (WSS) and oscillatory shear index (OSI) to risk of growth and rupture. However, such studies have reported contradictory results, emphasizing the need for in-depth multi-modality haemodynamic metric evaluation. In this work, we used in vivo 4D flow MRI data to inform in vitro particle velocimetry and CFD modalities in two patient-specific cerebral aneurysm models (basilar tip and internal carotid artery). Pulsatile volumetric particle velocimetry experiments were conducted, and the particle images were processed using Shake-the-Box, a particle tracking method. Distributions of normalized WSS and relative residence time were shown to be highly yet inconsistently affected by minor flow field and spatial resolution variations across modalities, and specific relationships among these should be explored in future work. Conversely, OSI, a non-dimensional parameter, was shown to be more robust to the varying assumptions, limitations and spatial resolutions of each subject and modality. These results suggest a need for further multi-modality analysis as well as development of non-dimensional haemodynamic parameters and correlation of such metrics to aneurysm risk of growth and rupture.
UR - http://www.scopus.com/inward/record.url?scp=85072031095&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85072031095&partnerID=8YFLogxK
U2 - 10.1098/rsif.2019.0465
DO - 10.1098/rsif.2019.0465
M3 - Article
C2 - 31506043
AN - SCOPUS:85072031095
SN - 1742-5689
VL - 16
JO - Journal of the Royal Society Interface
JF - Journal of the Royal Society Interface
IS - 158
M1 - 465
ER -