TY - JOUR
T1 - Nerve and Conduction Tissue Injury Caused by Contact with BioGlue
AU - LeMaire, Scott A.
AU - Ochoa, Lyssa N.
AU - Conklin, Lori D.
AU - Schmittling, Zachary C.
AU - Ündar, Akif
AU - Clubb, Fred J.
AU - Li Wang, Xing
AU - Coselli, Joseph S.
AU - Fraser, Charles D.
N1 - Funding Information:
Funding for this study was primarily provided by the Michael E. DeBakey Department of Surgery seed fund and by Charles D. Fraser, Jr., M.D. Additional funding, as well as the BioGlue surgical adhesive and the application devices, were provided by CryoLife, Inc.
PY - 2007/12
Y1 - 2007/12
N2 - Background: BioGlue-a surgical adhesive composed of bovine albumin and glutaraldehyde-is commonly used in cardiovascular operations. The objectives of this study were to determine whether BioGlue injures nerves and cardiac conduction tissues, and whether a water-soluble gel barrier protects against such injury. Materials and methods: In 18 pigs, diaphragmatic excursion during direct phrenic nerve stimulation was measured at baseline and at 3 and 30 min after nerve exposure to albumin (n = 3), glutaraldehyde (n = 3), BioGlue (n = 6), or water-soluble gel followed by BioGlue (n = 6). Additionally, BioGlue was applied to the cavoatrial junction overlying the sinoatrial node (SAN), either alone (n = 12) or after application of gel (n = 6). Results: Mean diaphragmatic excursions in the BioGlue and glutaraldehyde groups were lower at 3 min and 30 min than in the albumin group (P < 0.05). Mean excursions in the gel group were similar to those of the albumin group (P = 0.9). Five BioGlue pigs (83%) and one gel pig (17%) had diaphragmatic paralysis by 30 min (P < 0.05 and P = 0.3 versus albumin, respectively). Coagulation necrosis extended into the myocardium at the cavoatrial junction in all 12 BioGlue pigs but only two gel pigs (33%, P < 0.01). Two BioGlue pigs (17%), but no gel pigs, had focal SAN degeneration and persistent bradycardia (P < 0.01). Conclusions: BioGlue causes acute nerve injury and myocardial necrosis that can lead to SAN damage. A water-soluble gel barrier is protective.
AB - Background: BioGlue-a surgical adhesive composed of bovine albumin and glutaraldehyde-is commonly used in cardiovascular operations. The objectives of this study were to determine whether BioGlue injures nerves and cardiac conduction tissues, and whether a water-soluble gel barrier protects against such injury. Materials and methods: In 18 pigs, diaphragmatic excursion during direct phrenic nerve stimulation was measured at baseline and at 3 and 30 min after nerve exposure to albumin (n = 3), glutaraldehyde (n = 3), BioGlue (n = 6), or water-soluble gel followed by BioGlue (n = 6). Additionally, BioGlue was applied to the cavoatrial junction overlying the sinoatrial node (SAN), either alone (n = 12) or after application of gel (n = 6). Results: Mean diaphragmatic excursions in the BioGlue and glutaraldehyde groups were lower at 3 min and 30 min than in the albumin group (P < 0.05). Mean excursions in the gel group were similar to those of the albumin group (P = 0.9). Five BioGlue pigs (83%) and one gel pig (17%) had diaphragmatic paralysis by 30 min (P < 0.05 and P = 0.3 versus albumin, respectively). Coagulation necrosis extended into the myocardium at the cavoatrial junction in all 12 BioGlue pigs but only two gel pigs (33%, P < 0.01). Two BioGlue pigs (17%), but no gel pigs, had focal SAN degeneration and persistent bradycardia (P < 0.01). Conclusions: BioGlue causes acute nerve injury and myocardial necrosis that can lead to SAN damage. A water-soluble gel barrier is protective.
UR - http://www.scopus.com/inward/record.url?scp=36049048986&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=36049048986&partnerID=8YFLogxK
U2 - 10.1016/j.jss.2006.10.014
DO - 10.1016/j.jss.2006.10.014
M3 - Article
C2 - 17765925
AN - SCOPUS:36049048986
SN - 0022-4804
VL - 143
SP - 286
EP - 293
JO - Journal of Surgical Research
JF - Journal of Surgical Research
IS - 2
ER -