Abstract
Immunoaffinity chromatography (IAC) for the purification of polychlorinated dibenzo-p-dioxins and furans (PCDD/Fs) from biological samples was explored as a means to simplify the cleanup procedure and thereby decrease the time and cost of dioxin analysis. A monoclonal antibody (DD3) was used to produce IAC columns and to isolate the PCDD/Fs from serum. Native and 13C-labeled PCDD/Fs were spiked at the ppq to ppt range into serum. Quantitation of the PCDD/Fs was performed by a standard dioxin analytical method, i.e. high-resolution gas chromatography-mass spectrometry (GC-MS), which was easily compatible with IAC. Five of the most toxic PCDD/Fs consistently showed acceptable recoveries (>25%) and were reliably quantitated. The congeners specifically recovered by this method represent almost 80% of the toxic equivalency of dioxins and furans present in the serum samples. Dioxin-like polychlorinated biphenyls (PCBs) were not recognized by this antibody column. Compared to conventional dioxin cleanup methods, IAC decreased solvent usage by 1.5 l/sample and took only 2 h to process a sample for analysis.
Original language | English (US) |
---|---|
Pages (from-to) | 285-293 |
Number of pages | 9 |
Journal | Journal of Chromatography B: Biomedical Sciences and Applications |
Volume | 757 |
Issue number | 2 |
DOIs | |
State | Published - Jun 15 2001 |
All Science Journal Classification (ASJC) codes
- General Chemistry