T1 - Operation of a high frequency piezoelectric ultrasound array with an application specific integrated circuit
AU - Bernassau, Anne Lyse
AU - Button, Tim
AU - Choi, Kyusun
AU - Cochran, Sandy
AU - Demore, Christine
AU - Garcia-Gancedo, Luis
AU - Hutson, David
AU - Jackson, Tom
AU - Kim, Hyunsoo
AU - Kim, Insoo
AU - Meggs, Carl
AU - Trolier-McKinstry, Susan
AU - Tutwiler, Rick
N1 - Copyright:
Copyright 2010 Elsevier B.V., All rights reserved.
PY - 2009
Y1 - 2009
N2 - Integration of a piezoelectric high frequency ultrasound (HFUS) array with a microfabricated application specific integrated circuit (ASIC) performing a range of functions has several advantages for ultrasound imaging. The number of signal cables between the array/electronics and the data acquisition / imaging system can be reduced, cutting costs and increasing functionality. Electrical impedance matching is also simplified and the same approach can reduce overall system dimensions for applications such as endoscopic ultrasound. The work reported in this paper demonstrates early ASIC operation with a piezocomposite HFUS array operating at approximately 30 MHz. The array was tested in three different modes. Clear signals were seen in catch-mode, with an external transducer as a source of ultrasound, and in pitch-mode with the external transducer as a receiver. Pitch-catch mode was also tested successfully, using sequential excitation on three array elements, and viable signals were detected. However, these were relatively small and affected by interference from mixed-signal sources in the ASIC. Nevertheless, the functionality and compatibility of the two main components of an integrated HFUS - ASIC device have been demonstrated and the means of further optimization are evident.
AB - Integration of a piezoelectric high frequency ultrasound (HFUS) array with a microfabricated application specific integrated circuit (ASIC) performing a range of functions has several advantages for ultrasound imaging. The number of signal cables between the array/electronics and the data acquisition / imaging system can be reduced, cutting costs and increasing functionality. Electrical impedance matching is also simplified and the same approach can reduce overall system dimensions for applications such as endoscopic ultrasound. The work reported in this paper demonstrates early ASIC operation with a piezocomposite HFUS array operating at approximately 30 MHz. The array was tested in three different modes. Clear signals were seen in catch-mode, with an external transducer as a source of ultrasound, and in pitch-mode with the external transducer as a receiver. Pitch-catch mode was also tested successfully, using sequential excitation on three array elements, and viable signals were detected. However, these were relatively small and affected by interference from mixed-signal sources in the ASIC. Nevertheless, the functionality and compatibility of the two main components of an integrated HFUS - ASIC device have been demonstrated and the means of further optimization are evident.
UR - http://www.scopus.com/inward/record.url?scp=77952808781&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=77952808781&partnerID=8YFLogxK
U2 - 10.1109/ULTSYM.2009.5441707
DO - 10.1109/ULTSYM.2009.5441707
M3 - Conference contribution
AN - SCOPUS:77952808781
SN - 9781424443895
T3 - Proceedings - IEEE Ultrasonics Symposium
BT - 2009 IEEE International Ultrasonics Symposium and Short Courses, IUS 2009
T2 - 2009 IEEE International Ultrasonics Symposium, IUS 2009
Y2 - 20 September 2009 through 23 September 2009
ER -