TY - JOUR
T1 - Percutaneous complete repair of failed mitral valve prosthesis
T2 - Simultaneous closure of mitral paravalvular leaks and transcatheter mitral valve implantation - Single-centre experience
AU - Kliger, Chad
AU - Angulo, Rocio
AU - Maranan, Leandro
AU - Kumar, Robert
AU - Jelnin, Vladimir
AU - Kronzon, Itzhak
AU - Fontana, Gregory P.
AU - Plestis, Konstadinos
AU - Patel, Nirav
AU - Perk, Gila
AU - Ruiz, Carlos E.
N1 - Publisher Copyright:
© Europa Digital & Publishing 2015. All rights reserved.
PY - 2015/3/1
Y1 - 2015/3/1
N2 - Aims: Structural deterioration and paravalvular leak (PVL) are complications associated with surgically implanted prosthetic valves, historically requiring reoperation. We present our experience of complete transcatheter repair of a degenerated mitral bioprosthesis. Methods and results: From March 2012 to October 2012, we reviewed consecutive, high-risk surgical patients (n=5) who underwent transcatheter repair of a failed mitral bioprosthesis with severe paravalvular regurgitation (PVR). Manufacturer valve sizes ranged from 27 to 33 mm, regurgitation (n=1), stenosis (n=1), or both (n=3). Percutaneous transapical and transseptal access were achieved with PVL closure performed transapically. An arteriovenous rail was created for transseptal delivery of a Melody valve. All patients had successful PVL closure with no residual PVR. Valve-in-valve (ViV) implantation was successful in four patients. Overall, mean transvalvular mitral gradient was 11.2 mmHg pre-procedure which improved to 5 mmHg post-procedure. Improvement of NYHA Class ≥2 was achieved in all patients (19±3 months). One patient had controlled Melody valve embolisation which required emergent surgical replacement. Inner valve diameter was 26 mm, too large for Melody valve implantation. Conclusions: Complete transcatheter repair of a degenerated mitral bioprosthesis with PVR can be performed in the high-risk patient. Accurate measurement is necessary prior to intervention, with concern for embolisation among the larger valve sizes (>31 mm).
AB - Aims: Structural deterioration and paravalvular leak (PVL) are complications associated with surgically implanted prosthetic valves, historically requiring reoperation. We present our experience of complete transcatheter repair of a degenerated mitral bioprosthesis. Methods and results: From March 2012 to October 2012, we reviewed consecutive, high-risk surgical patients (n=5) who underwent transcatheter repair of a failed mitral bioprosthesis with severe paravalvular regurgitation (PVR). Manufacturer valve sizes ranged from 27 to 33 mm, regurgitation (n=1), stenosis (n=1), or both (n=3). Percutaneous transapical and transseptal access were achieved with PVL closure performed transapically. An arteriovenous rail was created for transseptal delivery of a Melody valve. All patients had successful PVL closure with no residual PVR. Valve-in-valve (ViV) implantation was successful in four patients. Overall, mean transvalvular mitral gradient was 11.2 mmHg pre-procedure which improved to 5 mmHg post-procedure. Improvement of NYHA Class ≥2 was achieved in all patients (19±3 months). One patient had controlled Melody valve embolisation which required emergent surgical replacement. Inner valve diameter was 26 mm, too large for Melody valve implantation. Conclusions: Complete transcatheter repair of a degenerated mitral bioprosthesis with PVR can be performed in the high-risk patient. Accurate measurement is necessary prior to intervention, with concern for embolisation among the larger valve sizes (>31 mm).
UR - http://www.scopus.com/inward/record.url?scp=84927668027&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84927668027&partnerID=8YFLogxK
U2 - 10.4244/EIJY14M05_01
DO - 10.4244/EIJY14M05_01
M3 - Article
C2 - 24800978
AN - SCOPUS:84927668027
SN - 1774-024X
VL - 10
SP - 1336
EP - 1345
JO - EuroIntervention
JF - EuroIntervention
IS - 11
ER -