PERFORMANCE CURVES FOR EARTH TUBE HEAT EXCHANGERS.

V. M. Puri

Research output: Contribution to journalConference articlepeer-review

Abstract

A time dependent axisymmetric finite element formulation of an earth-tube system is used to evaluate its thermal performance characteristics. The parameters included in this system are: pipe diameter, pipe length, initial soil moisture concentration and temperature and ambient air temperature. Design curves for both heating and cooling are presented. A simple illustrative example for swine farrowing facility shows that the earth tube system is cost effective, and the system payback period is less than 5 years.

Original languageEnglish (US)
JournalPaper - American Society of Agricultural Engineers
StatePublished - 1984

All Science Journal Classification (ASJC) codes

  • Agricultural and Biological Sciences (miscellaneous)

Fingerprint

Dive into the research topics of 'PERFORMANCE CURVES FOR EARTH TUBE HEAT EXCHANGERS.'. Together they form a unique fingerprint.