TY - JOUR
T1 - Peri-implant stress correlates with bone and cement morphology
T2 - Micro-FE modeling of implanted cadaveric glenoids
AU - Wee, Hwabok
AU - Armstrong, April D.
AU - Flint, Wesley W.
AU - Kunselman, Allen R.
AU - Lewis, Gregory S.
N1 - Publisher Copyright:
© 2015 Orthopaedic Research Society. Published by Wiley Periodicals, Inc.
PY - 2015/11/1
Y1 - 2015/11/1
N2 - Aseptic loosening of cemented joint replacements is a complex biological and mechanical process, and remains a clinical concern especially in patients with poor bone quality. Utilizing high resolution finite element analysis of a series of implanted cadaver glenoids, the objective of this study was to quantify relationships between construct morphology and resulting mechanical stresses in cement and trabeculae. Eight glenoid cadavers were implanted with a cemented central peg implant. Specimens were imaged by micro-CT, and subject-specific finite element models were developed. Bone volume fraction, glenoid width, implant-cortex distance, cement volume, cement-cortex contact, and cement-bone interface area were measured. Axial loading was applied to the implant of each model and stress distributions were characterized. Correlation analysis was completed across all specimens for pairs of morphological and mechanical variables. The amount of trabecular bone with high stress was strongly negatively correlated with both cement volume and contact between the cement and cortex (r = -0.85 and -0.84, p < 0.05). Bone with high stress was also correlated with both glenoid width and implant-cortex distance. Contact between the cement and underlying cortex may dramatically reduce trabecular bone stresses surrounding the cement, and this contact depends on bone shape, cement amount, and implant positioning.
AB - Aseptic loosening of cemented joint replacements is a complex biological and mechanical process, and remains a clinical concern especially in patients with poor bone quality. Utilizing high resolution finite element analysis of a series of implanted cadaver glenoids, the objective of this study was to quantify relationships between construct morphology and resulting mechanical stresses in cement and trabeculae. Eight glenoid cadavers were implanted with a cemented central peg implant. Specimens were imaged by micro-CT, and subject-specific finite element models were developed. Bone volume fraction, glenoid width, implant-cortex distance, cement volume, cement-cortex contact, and cement-bone interface area were measured. Axial loading was applied to the implant of each model and stress distributions were characterized. Correlation analysis was completed across all specimens for pairs of morphological and mechanical variables. The amount of trabecular bone with high stress was strongly negatively correlated with both cement volume and contact between the cement and cortex (r = -0.85 and -0.84, p < 0.05). Bone with high stress was also correlated with both glenoid width and implant-cortex distance. Contact between the cement and underlying cortex may dramatically reduce trabecular bone stresses surrounding the cement, and this contact depends on bone shape, cement amount, and implant positioning.
UR - http://www.scopus.com/inward/record.url?scp=84942819232&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84942819232&partnerID=8YFLogxK
U2 - 10.1002/jor.22933
DO - 10.1002/jor.22933
M3 - Article
C2 - 25929691
AN - SCOPUS:84942819232
SN - 0736-0266
VL - 33
SP - 1671
EP - 1679
JO - Journal of Orthopaedic Research
JF - Journal of Orthopaedic Research
IS - 11
ER -