TY - JOUR
T1 - Point-of-care assay platform for quantifying active enzymes to femtomolar levels using measurements of time as the readout
AU - Lewis, Gregory G.
AU - Robbins, Jessica S.
AU - Phillips, Scott T.
PY - 2013/11/5
Y1 - 2013/11/5
N2 - This Article describes a strategy for quantifying active enzyme analytes in a paper-based device by measuring the time for a reference region in the paper to turn green relative to an assay region. The assay requires a single step by the user, yet accounts for variations in sample volume, assay temperature, humidity, and contaminants in a sample that would otherwise prevent a quantitative measurement. The assay is capable of measuring enzymes in the low to mid femtomolar range with measurement times that range from ∼30 s to ∼15 min (lower measurement times correspond to lower quantities of the analyte). Different targets can be selected in the assay by changing a small molecule reagent within the paper-based device, and the sensitivity and dynamic range of the assays can be tuned easily by changing the composition and quantity of a signal amplification reagent or by modifying the configuration of the paper-based microfluidic device. By tuning these parameters, limits-of-detection for assays can be adjusted over an analyte concentration range of low femtomolar to low nanomolar, with dynamic ranges for the assays of at least 1 order of magnitude. Furthermore, the assay strategy is compatible with complex fluids such as serum.
AB - This Article describes a strategy for quantifying active enzyme analytes in a paper-based device by measuring the time for a reference region in the paper to turn green relative to an assay region. The assay requires a single step by the user, yet accounts for variations in sample volume, assay temperature, humidity, and contaminants in a sample that would otherwise prevent a quantitative measurement. The assay is capable of measuring enzymes in the low to mid femtomolar range with measurement times that range from ∼30 s to ∼15 min (lower measurement times correspond to lower quantities of the analyte). Different targets can be selected in the assay by changing a small molecule reagent within the paper-based device, and the sensitivity and dynamic range of the assays can be tuned easily by changing the composition and quantity of a signal amplification reagent or by modifying the configuration of the paper-based microfluidic device. By tuning these parameters, limits-of-detection for assays can be adjusted over an analyte concentration range of low femtomolar to low nanomolar, with dynamic ranges for the assays of at least 1 order of magnitude. Furthermore, the assay strategy is compatible with complex fluids such as serum.
UR - http://www.scopus.com/inward/record.url?scp=84887677759&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84887677759&partnerID=8YFLogxK
U2 - 10.1021/ac402415v
DO - 10.1021/ac402415v
M3 - Article
C2 - 24074247
AN - SCOPUS:84887677759
SN - 0003-2700
VL - 85
SP - 10432
EP - 10439
JO - Analytical Chemistry
JF - Analytical Chemistry
IS - 21
ER -