Position reconstruction in LUX

  • D. S. Akerib
  • , S. Alsum
  • , H. M. Arauandjo
  • , X. Bai
  • , A. J. Bailey
  • , J. Balajthy
  • , P. Beltrame
  • , E. P. Bernard
  • , A. Bernstein
  • , T. P. Biesiadzinski
  • , E. M. Boulton
  • , P. Braands
  • , D. Byram
  • , S. B. Cahn
  • , M. C. Carmona-Benitez
  • , C. Chan
  • , A. Currie
  • , J. E. Cutter
  • , T. J.R. Davison
  • , A. Dobi
  • E. Druszkiewicz, B. N. Edwards, S. R. Fallon, A. Fan, S. Fiorucci, R. J. Gaitskell, J. Genovesi, C. Ghag, M. G.D. Gilchriese, C. R. Hall, M. Hanhardt, S. J. Haselschwardt, S. A. Hertel, D. P. Hogan, M. Horn, D. Q. Huang, C. M. Ignarra, R. G. Jacobsen, W. Ji, K. Kamdin, K. Kazkaz, D. Khaitan, R. Knoche, N. A. Larsen, B. G. Lenardo, K. T. Lesko, A. Lindote, M. I. Lopes, A. Manalaysay, R. L. Mannino, M. F. Marzioni, D. N. McKinsey, D. M. Mei, J. Mock, M. Moongweluwan, J. A. Morad, A. St J. Murphy, C. Nehrkorn, H. N. Nelson, F. Neves, K. O'Sullivan, K. C. Oliver-Mallory, K. J. Palladino, E. K. Pease, C. Rhyne, S. Shaw, T. A. Shutt, C. Silva, M. Solmaz, V. N. Solovov, P. Sorensen, T. J. Sumner, M. Szydagis, D. J. Taylor, W. C. Taylor, B. P. Tennyson, P. A. Terman, D. R. Tiedt, W. H. To, M. Tripathi, L. Tvrznikova, S. Uvarov, V. Velan, J. R. Verbus, R. C. Webb, J. T. White, T. J. Whitis, M. S. Witherell, F. L.H. Wolfs, J. Xu, K. Yazdani, S. K. Young, C. Zhang

Research output: Contribution to journalArticlepeer-review

Abstract

The (x, y) position reconstruction method used in the analysis of the complete exposure of the Large Underground Xenon (LUX) experiment is presented. The algorithm is based on a statistical test that makes use of an iterative method to recover the photomultiplier tube (PMT) light response directly from the calibration data. The light response functions make use of a two dimensional functional form to account for the photons reflected on the inner walls of the detector. To increase the resolution for small pulses, a photon counting technique was employed to describe the response of the PMTs. The reconstruction was assessed with calibration data including 83mKr (releasing a total energy of 41.5 keV) and 3H (andbeta;- with Q = 18.6 keV) decays, and a deuterium-deuterium (D-D) neutron beam (2.45 MeV) . Within the detector's fiducial volume, the reconstruction has achieved an (x, y) position uncertainty of andsigma; = 0.82 cm and andsigma; = 0.17 cm for events of only 200 and 4,000 detected electroluminescence photons respectively. Such signals are associated with electron recoils of energies andsim;0.25 keV and andsim;10 keV, respectively. The reconstructed position of the smallest events with a single electron emitted from the liquid surface (22 detected photons) has a horizontal (x, y) uncertainty of 2.13 cm.

Original languageEnglish (US)
Article numberP02001
JournalJournal of Instrumentation
Volume13
Issue number2
DOIs
StatePublished - Feb 1 2018

All Science Journal Classification (ASJC) codes

  • Instrumentation
  • Mathematical Physics

Fingerprint

Dive into the research topics of 'Position reconstruction in LUX'. Together they form a unique fingerprint.

Cite this