TY - JOUR
T1 - Quantitative assessment of peripheral limb perfusion using a modified distal arterial cannula in venoarterial ECMO settings
AU - Foltan, Maik
AU - Philipp, Alois
AU - Göbölös, Laszlo
AU - Holzamer, Andreas
AU - Schneckenpointner, Roland
AU - Lehle, Karla
AU - Kornilov, Igor
AU - Schmid, Christof
AU - Lunz, Dirk
N1 - Publisher Copyright:
© The Author(s) 2019.
PY - 2019/9/1
Y1 - 2019/9/1
N2 - In cases of severe cardiopulmonary deterioration, quick establishment of venoarterial extracorporeal membrane oxygenation (ECMO) represents a support modality. After successful arterial peripheral cannulation, a certain grade of peripheral limb malperfusion is a fairly common phenomenon. Detection of peripheral malperfusion is vital, since it can result in compartment syndrome or even loss of the affected limb. To prevent or resolve emerging lower limb ischaemia, a newly designed perfusion catheter is placed into the superficial femoral artery, distal to the arterial cannula via ECMO. The aim of our study was to evaluate flow and haemodynamic characteristics of this novel distal limb perfusion cannula for ECMO therapy and present these important findings for the first time. The distal perfusion cannula blood flow increases in linear correlation with ECMO blood flow The variability of distal perfusion cannula blood flow with a 15 Fr cannula ranges between 160 ± 0.40 mL min−1 at 1.5 L min−1 ECMO flow rate and 480 ± 80 mL min−1 at 5.0 L min−1 ECMO blood flow, respectively. Comparatively, the 17-Fr-sized cannula performs on a scale of 140 ± 20 to 390 ± 60 mL distal perfusion cannula blood flow at 1.5-5.0 L min−1 ECMO blood flow, respectively. The quantitative assessment of the distal perfusion cannula blood flow has revealed that distal perfusion cannula blood flow can measure up to 10% of the ECMO blood flow. Furthermore, it has been also well demonstrated that the novel distal perfusion cannula is sufficient to compensate peripheral limb ischaemia.
AB - In cases of severe cardiopulmonary deterioration, quick establishment of venoarterial extracorporeal membrane oxygenation (ECMO) represents a support modality. After successful arterial peripheral cannulation, a certain grade of peripheral limb malperfusion is a fairly common phenomenon. Detection of peripheral malperfusion is vital, since it can result in compartment syndrome or even loss of the affected limb. To prevent or resolve emerging lower limb ischaemia, a newly designed perfusion catheter is placed into the superficial femoral artery, distal to the arterial cannula via ECMO. The aim of our study was to evaluate flow and haemodynamic characteristics of this novel distal limb perfusion cannula for ECMO therapy and present these important findings for the first time. The distal perfusion cannula blood flow increases in linear correlation with ECMO blood flow The variability of distal perfusion cannula blood flow with a 15 Fr cannula ranges between 160 ± 0.40 mL min−1 at 1.5 L min−1 ECMO flow rate and 480 ± 80 mL min−1 at 5.0 L min−1 ECMO blood flow, respectively. Comparatively, the 17-Fr-sized cannula performs on a scale of 140 ± 20 to 390 ± 60 mL distal perfusion cannula blood flow at 1.5-5.0 L min−1 ECMO blood flow, respectively. The quantitative assessment of the distal perfusion cannula blood flow has revealed that distal perfusion cannula blood flow can measure up to 10% of the ECMO blood flow. Furthermore, it has been also well demonstrated that the novel distal perfusion cannula is sufficient to compensate peripheral limb ischaemia.
UR - http://www.scopus.com/inward/record.url?scp=85063036308&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85063036308&partnerID=8YFLogxK
U2 - 10.1177/0267659118816934
DO - 10.1177/0267659118816934
M3 - Article
C2 - 30864486
AN - SCOPUS:85063036308
SN - 0267-6591
VL - 34
SP - 503
EP - 507
JO - Perfusion (United Kingdom)
JF - Perfusion (United Kingdom)
IS - 6
ER -