TY - JOUR
T1 - Relationship of echocardiographic dyssynchrony to long-term survival after cardiac resynchronization therapy
AU - Gorcsan, John
AU - Oyenuga, Olusegun
AU - Habib, Phillip J.
AU - Tanaka, Hidekazu
AU - Adelstein, Evan C.
AU - Hara, Hideyuki
AU - McNamara, Dennis M.
AU - Saba, Samir
PY - 2010/11/9
Y1 - 2010/11/9
N2 - Background-: The ability of echocardiographic dyssynchrony to predict response to cardiac resynchronization therapy (CRT) has been unclear. Methods and results-: A prospective, longitudinal study was designed with predefined dyssynchrony indexes and outcome variables to test the hypothesis that baseline dyssynchrony is associated with long-term survival after CRT. We studied 229 consecutive class III to IV heart failure patients with ejection fraction ≤35% and QRS duration ≥120 milliseconds for CRT. Dyssynchrony before CRT was defined as tissue Doppler velocity opposing-wall delay ≥65 milliseconds, 12-site SD (Yu Index) ≥32 milliseconds, speckle tracking radial strain anteroseptal-to-posterior wall delay ≥130 milliseconds, or pulsed Doppler interventricular mechanical delay ≥40 milliseconds. Outcome was defined as freedom from death, heart transplantation, or left ventricular assist device implantation. Of 210 patients (89%) with dyssynchrony data available, there were 62 events: 47 deaths, 9 transplantations, and 6 left ventricular assist device implantations over 4 years. Event-free survival was associated with Yu Index (P=0.003), speckle tracking radial strain (P=0.003), and interventricular mechanical delay (P=0.019). When adjusted for confounding baseline variables of ischemic origin and QRS duration, Yu Index and radial strain dyssynchrony remained independently associated with outcome (P<0.05). Lack of radial dyssynchrony was particularly associated with unfavorable outcome in those with QRS duration of 120 to 150 milliseconds (P=0.002). Conclusions-: The absence of echocardiographic dyssynchrony was associated with significantly less favorable event-free survival after CRT. Patients with narrower QRS duration who lacked dyssynchrony had the least favorable long-term outcome. These observations support the relationship of dyssynchrony and CRT response.
AB - Background-: The ability of echocardiographic dyssynchrony to predict response to cardiac resynchronization therapy (CRT) has been unclear. Methods and results-: A prospective, longitudinal study was designed with predefined dyssynchrony indexes and outcome variables to test the hypothesis that baseline dyssynchrony is associated with long-term survival after CRT. We studied 229 consecutive class III to IV heart failure patients with ejection fraction ≤35% and QRS duration ≥120 milliseconds for CRT. Dyssynchrony before CRT was defined as tissue Doppler velocity opposing-wall delay ≥65 milliseconds, 12-site SD (Yu Index) ≥32 milliseconds, speckle tracking radial strain anteroseptal-to-posterior wall delay ≥130 milliseconds, or pulsed Doppler interventricular mechanical delay ≥40 milliseconds. Outcome was defined as freedom from death, heart transplantation, or left ventricular assist device implantation. Of 210 patients (89%) with dyssynchrony data available, there were 62 events: 47 deaths, 9 transplantations, and 6 left ventricular assist device implantations over 4 years. Event-free survival was associated with Yu Index (P=0.003), speckle tracking radial strain (P=0.003), and interventricular mechanical delay (P=0.019). When adjusted for confounding baseline variables of ischemic origin and QRS duration, Yu Index and radial strain dyssynchrony remained independently associated with outcome (P<0.05). Lack of radial dyssynchrony was particularly associated with unfavorable outcome in those with QRS duration of 120 to 150 milliseconds (P=0.002). Conclusions-: The absence of echocardiographic dyssynchrony was associated with significantly less favorable event-free survival after CRT. Patients with narrower QRS duration who lacked dyssynchrony had the least favorable long-term outcome. These observations support the relationship of dyssynchrony and CRT response.
UR - http://www.scopus.com/inward/record.url?scp=78649334752&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=78649334752&partnerID=8YFLogxK
U2 - 10.1161/CIRCULATIONAHA.110.954768
DO - 10.1161/CIRCULATIONAHA.110.954768
M3 - Article
C2 - 20975000
AN - SCOPUS:78649334752
SN - 0009-7322
VL - 122
SP - 1909
EP - 1918
JO - Circulation
JF - Circulation
IS - 19
ER -