TY - JOUR
T1 - Reliability of Continuous Shear Wave Elastography in the Pathological Patellar Tendon
AU - Ito, Naoaki
AU - Sigurðsson, Haraldur B.
AU - Pohlig, Ryan T.
AU - Cortes, Daniel H.
AU - Grävare Silbernagel, Karin
AU - Sprague, Andrew L.
N1 - Publisher Copyright:
© 2022 American Institute of Ultrasound in Medicine.
PY - 2023/5
Y1 - 2023/5
N2 - Objectives: Patellar tendon injuries occur via various mechanisms such as overuse, or due to surgical graft harvest for anterior cruciate ligament reconstruction (ACLR). Quantified patellar tendon stiffness after injury may help guide clinical care. Continuous shear wave elastography (cSWE) allows for the assessment of viscosity and shear modulus in tendons. The reliability of the measure, however, has not been established in the patellar tendon. The purpose of this study was to investigate the interrater reliability, intrarater reliability, and between-day stability of cSWE in both healthy and pathological patellar tendons. Methods: Participants with patellar tendinopathy (n = 13), history of ACLR using bone-patellar tendon-bone autograft (n = 9), and with no history of patellar tendon injury (n = 13) were recruited. cSWE was performed 4 times by multiple raters over 2 days. Intraclass correlations (ICC) and minimum detectable change (MDC95%) were calculated. Results: Good to excellent between-day stability were found for viscosity (ICC = 0.905, MDC95% = 8.3 Pa seconds) and shear modulus (ICC = 0.805, MDC95% = 27.4 kPa). The interrater reliability measures, however, were not as reliable (ICC = 0.591 and 0.532). Conclusions: cSWE is a reliable assessment tool for quantifying patellar tendon viscoelastic properties over time. It is recommended, however, that a single rater performs the measure as the interrater reliability was less than ideal.
AB - Objectives: Patellar tendon injuries occur via various mechanisms such as overuse, or due to surgical graft harvest for anterior cruciate ligament reconstruction (ACLR). Quantified patellar tendon stiffness after injury may help guide clinical care. Continuous shear wave elastography (cSWE) allows for the assessment of viscosity and shear modulus in tendons. The reliability of the measure, however, has not been established in the patellar tendon. The purpose of this study was to investigate the interrater reliability, intrarater reliability, and between-day stability of cSWE in both healthy and pathological patellar tendons. Methods: Participants with patellar tendinopathy (n = 13), history of ACLR using bone-patellar tendon-bone autograft (n = 9), and with no history of patellar tendon injury (n = 13) were recruited. cSWE was performed 4 times by multiple raters over 2 days. Intraclass correlations (ICC) and minimum detectable change (MDC95%) were calculated. Results: Good to excellent between-day stability were found for viscosity (ICC = 0.905, MDC95% = 8.3 Pa seconds) and shear modulus (ICC = 0.805, MDC95% = 27.4 kPa). The interrater reliability measures, however, were not as reliable (ICC = 0.591 and 0.532). Conclusions: cSWE is a reliable assessment tool for quantifying patellar tendon viscoelastic properties over time. It is recommended, however, that a single rater performs the measure as the interrater reliability was less than ideal.
UR - http://www.scopus.com/inward/record.url?scp=85141430982&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85141430982&partnerID=8YFLogxK
U2 - 10.1002/jum.16115
DO - 10.1002/jum.16115
M3 - Article
C2 - 36301665
AN - SCOPUS:85141430982
SN - 0278-4297
VL - 42
SP - 1047
EP - 1055
JO - Journal of Ultrasound in Medicine
JF - Journal of Ultrasound in Medicine
IS - 5
ER -