TY - JOUR
T1 - Replacement of the anterior cruciate ligament with a bone-ligament-bone anterior cruciate ligament allograft in dogs
AU - Vasseur, P. B.
AU - Rodrigo, J. J.
AU - Stevenson, S.
AU - Clark, G.
AU - Sharkey, N.
PY - 1987
Y1 - 1987
N2 - Acute replacement of the canine anterior cruciate ligament (ACL) with a frozen, bone-ligament-bone anterior cruciate ligament preparation was studied using biochemical, immunologic, and biomechanical testing methods. Nine dogs were used for the study, six dogs received allografts and three received autografts. No tissue antigen matching was performed. All nine dogs were killed nine months after surgery. Necropsy examination revealed that the ACL was not present in three joints (one autograft, two allografts). The two autograft and four allograft ligaments available for mechanical testing sustained mean maximum loads that were 10% and 14%, respectively, of the mean maximum loads sustained by the contralateral ACL. Autoradiography indicated that cellular activity was more pronounced in the autograft specimens. Hydroxyproline uptake was 200% and 45% of normal in the autograft and allograft ligaments, respectively. Both autograft and allograft specimens were producing Type I collagen at the time of klling. Antidonor dog leukocyte antigen (DLA) antibody was detected in the synovial fluid taken at the time of killing from six of six dogs that received allografts and in zero of three dogs that received autografts.
AB - Acute replacement of the canine anterior cruciate ligament (ACL) with a frozen, bone-ligament-bone anterior cruciate ligament preparation was studied using biochemical, immunologic, and biomechanical testing methods. Nine dogs were used for the study, six dogs received allografts and three received autografts. No tissue antigen matching was performed. All nine dogs were killed nine months after surgery. Necropsy examination revealed that the ACL was not present in three joints (one autograft, two allografts). The two autograft and four allograft ligaments available for mechanical testing sustained mean maximum loads that were 10% and 14%, respectively, of the mean maximum loads sustained by the contralateral ACL. Autoradiography indicated that cellular activity was more pronounced in the autograft specimens. Hydroxyproline uptake was 200% and 45% of normal in the autograft and allograft ligaments, respectively. Both autograft and allograft specimens were producing Type I collagen at the time of klling. Antidonor dog leukocyte antigen (DLA) antibody was detected in the synovial fluid taken at the time of killing from six of six dogs that received allografts and in zero of three dogs that received autografts.
UR - http://www.scopus.com/inward/record.url?scp=0023256699&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0023256699&partnerID=8YFLogxK
U2 - 10.1097/00003086-198706000-00037
DO - 10.1097/00003086-198706000-00037
M3 - Article
C2 - 3555926
AN - SCOPUS:0023256699
SN - 0009-921X
VL - 219
SP - 268
EP - 277
JO - Clinical orthopaedics and related research
JF - Clinical orthopaedics and related research
ER -