TY - JOUR
T1 - Role of positron emission tomography in staging esophageal cancer
AU - Luketich, James D.
AU - Schauer, Philip R.
AU - Meltzer, Carolyn Cidis
AU - Landreneau, Rodney J.
AU - Urso, G. Kathleen
AU - Townsend, David W.
AU - Ferson, Peter F.
AU - Keenan, Robert J.
AU - Belani, Chandra P.
N1 - Copyright:
Copyright 2007 Elsevier B.V., All rights reserved.
PY - 1997/9
Y1 - 1997/9
N2 - Background. Conventional noninvasive staging of esophageal cancer is inaccurate. This study investigated the role of positron emission tomography (PET) in staging esophageal cancer. Methods. Patients with potentially resectable esophageal cancer were included. A whole-body PET scan was acquired after injection of 18F-fluorodeoxyglucose and was evaluated for areas of increased focal uptake. Accuracy was determined by comparing PET with surgical staging. Results. Potentially resectable esophageal cancer was identified in 35 patients. Positron emission tomography detected nine sites of distant metastases missed by conventional scanning, but one false-negative PET scan occurred in a patient with a 2-mm liver lesion. There were 11 false- negative PET scans for small, intracapsular local-regional nodal metastases (mean diameter 5.2 mm; range 2 to 10 mm). For distant metastases, the sensitivity was 88%, the specificity was 93%, and the accuracy was 91%. For local-regional nodal metastases, the sensitivity was 45%, the specificity was 100%, and the accuracy was 48%. Conclusions. Positron emission tomography improved our ability to detect distant metastases missed by conventional noninvasive staging of esophageal cancer. Small local-regional nodal metastases are not identified by current PET technology. Early use of PET in the staging of patients with esophageal cancer could facilitate treatment planning and identifying unsuspected distant metastases in up to 20% of patients with a negative metastatic survey by conventional staging.
AB - Background. Conventional noninvasive staging of esophageal cancer is inaccurate. This study investigated the role of positron emission tomography (PET) in staging esophageal cancer. Methods. Patients with potentially resectable esophageal cancer were included. A whole-body PET scan was acquired after injection of 18F-fluorodeoxyglucose and was evaluated for areas of increased focal uptake. Accuracy was determined by comparing PET with surgical staging. Results. Potentially resectable esophageal cancer was identified in 35 patients. Positron emission tomography detected nine sites of distant metastases missed by conventional scanning, but one false-negative PET scan occurred in a patient with a 2-mm liver lesion. There were 11 false- negative PET scans for small, intracapsular local-regional nodal metastases (mean diameter 5.2 mm; range 2 to 10 mm). For distant metastases, the sensitivity was 88%, the specificity was 93%, and the accuracy was 91%. For local-regional nodal metastases, the sensitivity was 45%, the specificity was 100%, and the accuracy was 48%. Conclusions. Positron emission tomography improved our ability to detect distant metastases missed by conventional noninvasive staging of esophageal cancer. Small local-regional nodal metastases are not identified by current PET technology. Early use of PET in the staging of patients with esophageal cancer could facilitate treatment planning and identifying unsuspected distant metastases in up to 20% of patients with a negative metastatic survey by conventional staging.
UR - http://www.scopus.com/inward/record.url?scp=0030769847&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0030769847&partnerID=8YFLogxK
U2 - 10.1016/S0003-4975(97)00624-3
DO - 10.1016/S0003-4975(97)00624-3
M3 - Article
C2 - 9307471
AN - SCOPUS:0030769847
SN - 0003-4975
VL - 64
SP - 765
EP - 769
JO - Annals of Thoracic Surgery
JF - Annals of Thoracic Surgery
IS - 3
ER -