TY - JOUR
T1 - Rolling Circle Amplification-Coupled Glass Nanopore Counting of Mild Traumatic Brain Injury-Related Salivary miRNAs
AU - Dong, Ming
AU - Tang, Zifan
AU - Hicks, Steven
AU - Guan, Weihua
N1 - Publisher Copyright:
© 2022 American Chemical Society.
PY - 2022/3/8
Y1 - 2022/3/8
N2 - Mild traumatic brain injury (mTBI) could be underdiagnosed and underreported due to the delayed onset of symptoms and the conventional subjective assessment. Recent studies have suggested that salivary microRNAs (miRNAs) could be reliable biomarkers for objective mTBI diagnosis. In this work, we demonstrated a rolling circle amplification (RCA)-coupled resistive pulse-counting platform for profiling mTBI-related miRNAs, using easy-to-fabricate large glass nanopores (200 nm diameter). The method relies on the linear and specific elongation of the miRNA to a much larger RCA product, which the large glass nanopore can digitally count with a high signal-to-noise ratio. We developed and validated the RCA assay against let-7a, miR-30e, and miR-21. We demonstrated the quantification capability of this large glass nanopore counting platform for purified miRNAs as well as miRNAs in salivary total RNA background. Finally, we quantitatively evaluated the performance of profiling each individual miRNAs in a mixed analyte. Our results showed that the RCA-coupled large glass nanopore counting provides a promising and accessible alternative toward the clinical diagnosis of mTBI using salivary miRNAs.
AB - Mild traumatic brain injury (mTBI) could be underdiagnosed and underreported due to the delayed onset of symptoms and the conventional subjective assessment. Recent studies have suggested that salivary microRNAs (miRNAs) could be reliable biomarkers for objective mTBI diagnosis. In this work, we demonstrated a rolling circle amplification (RCA)-coupled resistive pulse-counting platform for profiling mTBI-related miRNAs, using easy-to-fabricate large glass nanopores (200 nm diameter). The method relies on the linear and specific elongation of the miRNA to a much larger RCA product, which the large glass nanopore can digitally count with a high signal-to-noise ratio. We developed and validated the RCA assay against let-7a, miR-30e, and miR-21. We demonstrated the quantification capability of this large glass nanopore counting platform for purified miRNAs as well as miRNAs in salivary total RNA background. Finally, we quantitatively evaluated the performance of profiling each individual miRNAs in a mixed analyte. Our results showed that the RCA-coupled large glass nanopore counting provides a promising and accessible alternative toward the clinical diagnosis of mTBI using salivary miRNAs.
UR - http://www.scopus.com/inward/record.url?scp=85125677136&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85125677136&partnerID=8YFLogxK
U2 - 10.1021/acs.analchem.1c04781
DO - 10.1021/acs.analchem.1c04781
M3 - Article
C2 - 35192325
AN - SCOPUS:85125677136
SN - 0003-2700
VL - 94
SP - 3865
EP - 3871
JO - Analytical Chemistry
JF - Analytical Chemistry
IS - 9
ER -