TY - JOUR
T1 - Salivastat
T2 - Direct-pcr and pooling of saliva samples collected in healthcare and community setting for sars-cov-2 mass surveillance
AU - Sahajpal, Nikhil S.
AU - Mondal, Ashis K.
AU - Ananth, Sudha
AU - Njau, Allan
AU - Ahluwalia, Pankaj
AU - Newnam, Gary
AU - Lozoya-Colinas, Adriana
AU - Hud, Nicholas V.
AU - Kota, Vamsi
AU - Ross, Ted M.
AU - Reid, Michelle D.
AU - Fulzele, Sadanand
AU - Chaubey, Alka
AU - Hegde, Madhuri
AU - Rojiani, Amyn M.
AU - Kolhe, Ravindra
N1 - Publisher Copyright:
© 2021 by the authors. Licensee MDPI, Basel, Switzerland.
PY - 2021
Y1 - 2021
N2 - Objectives: Limitations of widespread current COVID-19 diagnostic testing exist in both the pre-analytical and analytical stages. To alleviate these limitations, we developed a universal saliva processing protocol (SalivaSTAT) that would enable an extraction-free RT-PCR test using commercially available RT-PCR kits. Methods: We optimized saliva collection devices, heat-shock treatment, and homogenization. Saliva samples (879) previously tested using the FDA-EUA method were reevaluated with the optimized SalivaSTAT protocol using two widely available commercial RT-PCR kits. A five-sample pooling strategy was evaluated as per FDA guidelines. Results: Saliva collection (done without any media) showed performance comparable to that of the FDA-EUA method. The SalivaSTAT protocol was optimized by incubating saliva samples at 95◦ C for 30-min and homogenization, followed by RT-PCR assay. The clinical sample evaluation of 630 saliva samples using the SalivaSTAT protocol with PerkinElmer (600-samples) and CDC (30-samples) RT-PCR assay achieved positive (PPA) and negative percent agreements (NPAs) of 95.0% and 100%, respectively. The LoD was established as ~60–180 copies/mL by absolute quantification. Furthermore, a five-sample-pooling evaluation using 250 saliva samples achieved a PPA and NPA of 92% and 100%, respectively. Conclusion: We have optimized an extraction-free RT-PCR assay for saliva samples that demonstrates comparable performance to FDA-EUA assay (Extraction and RT-PCR).
AB - Objectives: Limitations of widespread current COVID-19 diagnostic testing exist in both the pre-analytical and analytical stages. To alleviate these limitations, we developed a universal saliva processing protocol (SalivaSTAT) that would enable an extraction-free RT-PCR test using commercially available RT-PCR kits. Methods: We optimized saliva collection devices, heat-shock treatment, and homogenization. Saliva samples (879) previously tested using the FDA-EUA method were reevaluated with the optimized SalivaSTAT protocol using two widely available commercial RT-PCR kits. A five-sample pooling strategy was evaluated as per FDA guidelines. Results: Saliva collection (done without any media) showed performance comparable to that of the FDA-EUA method. The SalivaSTAT protocol was optimized by incubating saliva samples at 95◦ C for 30-min and homogenization, followed by RT-PCR assay. The clinical sample evaluation of 630 saliva samples using the SalivaSTAT protocol with PerkinElmer (600-samples) and CDC (30-samples) RT-PCR assay achieved positive (PPA) and negative percent agreements (NPAs) of 95.0% and 100%, respectively. The LoD was established as ~60–180 copies/mL by absolute quantification. Furthermore, a five-sample-pooling evaluation using 250 saliva samples achieved a PPA and NPA of 92% and 100%, respectively. Conclusion: We have optimized an extraction-free RT-PCR assay for saliva samples that demonstrates comparable performance to FDA-EUA assay (Extraction and RT-PCR).
UR - http://www.scopus.com/inward/record.url?scp=85106956865&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85106956865&partnerID=8YFLogxK
U2 - 10.3390/diagnostics11050904
DO - 10.3390/diagnostics11050904
M3 - Article
C2 - 34069462
AN - SCOPUS:85106956865
SN - 2075-4418
VL - 11
JO - Diagnostics
JF - Diagnostics
IS - 5
M1 - 904
ER -