T1 - Sevoflurane and Isoflurane—Pharmacokinetics, Hemodynamic Stability, and Cardioprotective Effects During Cardiopulmonary Bypass
AU - Freiermuth, David
AU - Mets, Berend
AU - Bolliger, Daniel
AU - Reuthebuch, Oliver
AU - Doebele, Thomas
AU - Scholz, Markus
AU - Gregor, Michael
AU - Haschke, Matthias
AU - Seeberger, Manfred Daniel
AU - Fassl, Jens
N1 - Funding Information:
This work was supported by an unrestricted research grant from AbbVie AG Switzerland; Penn State Hershey Medical Center, Department of Anesthesiology; and the Department of Anesthesiology and Intensive Care Medicine, University Hospital Basel. The authors would like to thank Manfred Moeller, PhD, Institute of Hygiene and Environmental Medicine, Rheinisch-Westfaelische University of Aachen, Germany for his expertise and the gas-chromatography measurements.
Publisher Copyright:
© 2016 Elsevier Inc.
PY - 2016/12/1
Y1 - 2016/12/1
N2 - Objectives This study aimed to evaluate the pharmacokinetic profiles of sevoflurane and isoflurane during use of minimized extracorporeal circulation to perform coronary artery bypass graft surgery. Furthermore, cardiovascular stability during bypass and the postoperative release of troponins were evaluated. Design Prospective, randomized study. Setting University hospital. Participants The study comprised 31 adult patients undergoing coronary artery bypass grafting. Interventions The pharmacokinetic measurements of the concentration of the volatile anesthetics in the arterial and venous blood, air inlet, air outlet, and gas exhaust of the extracorporeal circulation were recorded. Secondary end-points were cardiovascular stability during bypass, amount of postoperative release of troponin, time to extubation, time to discharge from the intensive care unit and the hospital, and 30-day mortality. Measurements and Main Results Thirty patients completed the protocol. The pharmacokinetics of isoflurane and sevoflurane were almost identical, with a rapid wash-in (time to reach 50% of arterial steady state) concentration of 0.87±0.97 minutes and 1.14±0.35 minutes for isoflurane and sevoflurane, respectively, and a biphasic venous elimination with a terminal half-life of approximately 10 minutes for both compounds. There was a correlation between the gas inlet and the gas exhaust of the extracorporeal circulation. No difference in cardiovascular stability was found. High-sensitivity troponin concentrations on the first postoperative morning were 0.355±0.312 µg/mL and 0.225±0.111 µg/mL in the isoflurane and sevoflurane groups, respectively (p = 0.147). Conclusions The study found similar pharmacokinetics regarding wash-in and wash-out for sevoflurane and isoflurane. In addition, no difference in cardiovascular stability was found. The markers of cardiac damage were not different between the two anesthetics. Based on these data, sevoflurane and isoflurane might be used equivalently in patients undergoing coronary artery bypass graft surgery with extracorporeal circulation.
AB - Objectives This study aimed to evaluate the pharmacokinetic profiles of sevoflurane and isoflurane during use of minimized extracorporeal circulation to perform coronary artery bypass graft surgery. Furthermore, cardiovascular stability during bypass and the postoperative release of troponins were evaluated. Design Prospective, randomized study. Setting University hospital. Participants The study comprised 31 adult patients undergoing coronary artery bypass grafting. Interventions The pharmacokinetic measurements of the concentration of the volatile anesthetics in the arterial and venous blood, air inlet, air outlet, and gas exhaust of the extracorporeal circulation were recorded. Secondary end-points were cardiovascular stability during bypass, amount of postoperative release of troponin, time to extubation, time to discharge from the intensive care unit and the hospital, and 30-day mortality. Measurements and Main Results Thirty patients completed the protocol. The pharmacokinetics of isoflurane and sevoflurane were almost identical, with a rapid wash-in (time to reach 50% of arterial steady state) concentration of 0.87±0.97 minutes and 1.14±0.35 minutes for isoflurane and sevoflurane, respectively, and a biphasic venous elimination with a terminal half-life of approximately 10 minutes for both compounds. There was a correlation between the gas inlet and the gas exhaust of the extracorporeal circulation. No difference in cardiovascular stability was found. High-sensitivity troponin concentrations on the first postoperative morning were 0.355±0.312 µg/mL and 0.225±0.111 µg/mL in the isoflurane and sevoflurane groups, respectively (p = 0.147). Conclusions The study found similar pharmacokinetics regarding wash-in and wash-out for sevoflurane and isoflurane. In addition, no difference in cardiovascular stability was found. The markers of cardiac damage were not different between the two anesthetics. Based on these data, sevoflurane and isoflurane might be used equivalently in patients undergoing coronary artery bypass graft surgery with extracorporeal circulation.
UR - http://www.scopus.com/inward/record.url?scp=84998774642&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84998774642&partnerID=8YFLogxK
U2 - 10.1053/j.jvca.2016.07.011
DO - 10.1053/j.jvca.2016.07.011
M3 - Article
C2 - 27692704
AN - SCOPUS:84998774642
SN - 1053-0770
VL - 30
SP - 1494
EP - 1501
JO - Journal of cardiothoracic and vascular anesthesia
JF - Journal of cardiothoracic and vascular anesthesia
IS - 6
ER -