TY - JOUR
T1 - Simplified method for free SO2 measurement using gas detection tubes
AU - Pegram, Zachary
AU - Kwasniewski, Misha T.
AU - Sacks, Gavin L.
N1 - Copyright:
Copyright 2013 Elsevier B.V., All rights reserved.
PY - 2013/9
Y1 - 2013/9
N2 - The classic Monier-Williams method for free sulfur dioxide (SO2) measurement in wines was modified using inexpensive SO2detection tubes developed for the mining industry. An acidified wine sample was treated with an antacid tablet to evolve CO2in situ and the gas flow directed to a commercial SO2detection tube. The length of tube that changed color was proportional to the original free SO2concentration. Initial calibration of the tubes was performed in model wines using aeration-oxidation (A-O) as a reference method. Using a 20 mL sample, the SO2tube method achieved a linear response from 5 to 40 mg/L. Accuracy was evaluated by measuring free SO2concentrations in 16 wines (seven whites, nine reds) by both the SO2tube and A-O reference methods. Free SO2concentrations for individual wines measured by each method were within ±2 mg/mL and the RMSE was 0.89 mg/L. The limit of detection of the SO2tube method was 3.3 mg/L in wine. The SO2tube method has several advantages over A-O, including requiring less time per analysis and no specialized glassware or equipment. The major consumable cost is the detection tubes, which can be conserved in exchange for precision by using smaller sample sizes.
AB - The classic Monier-Williams method for free sulfur dioxide (SO2) measurement in wines was modified using inexpensive SO2detection tubes developed for the mining industry. An acidified wine sample was treated with an antacid tablet to evolve CO2in situ and the gas flow directed to a commercial SO2detection tube. The length of tube that changed color was proportional to the original free SO2concentration. Initial calibration of the tubes was performed in model wines using aeration-oxidation (A-O) as a reference method. Using a 20 mL sample, the SO2tube method achieved a linear response from 5 to 40 mg/L. Accuracy was evaluated by measuring free SO2concentrations in 16 wines (seven whites, nine reds) by both the SO2tube and A-O reference methods. Free SO2concentrations for individual wines measured by each method were within ±2 mg/mL and the RMSE was 0.89 mg/L. The limit of detection of the SO2tube method was 3.3 mg/L in wine. The SO2tube method has several advantages over A-O, including requiring less time per analysis and no specialized glassware or equipment. The major consumable cost is the detection tubes, which can be conserved in exchange for precision by using smaller sample sizes.
UR - http://www.scopus.com/inward/record.url?scp=84883313371&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84883313371&partnerID=8YFLogxK
U2 - 10.5344/ajev.2013.13003
DO - 10.5344/ajev.2013.13003
M3 - Article
AN - SCOPUS:84883313371
SN - 0002-9254
VL - 64
SP - 405
EP - 410
JO - American Journal of Enology and Viticulture
JF - American Journal of Enology and Viticulture
IS - 3
ER -