Abstract
A reversed phased HPLC method with photodiode array detection was used to monitor the stability of opioid growth factor (OGF; [Met5]- enkephalin) in sterile saline for 1, 2, and 8 weeks, and stored at -17°C, 4°C, and 23°C. Samples maintained at -17°C had 97% of the initial OGF concentration after 2 months, whereas those stored at 4°C had 94% of the original concentration. Preparations housed at 22°C had reductions of 6-12% by the 8th week. These data provide important information about storage of OGF for clinical applications.
| Original language | English (US) |
|---|---|
| Pages (from-to) | 151-157 |
| Number of pages | 7 |
| Journal | Journal of Liquid Chromatography and Related Technologies |
| Volume | 29 |
| Issue number | 2 |
| DOIs | |
| State | Published - Jan 1 2006 |