Abstract
A high temperature transducer composed of aluminum nitride is demonstrated. The aluminum nitride is intended to be utilized in a stepped sparse phased array. The stepped sparse phased array is explained demonstrated and modeled.
| Original language | English (US) |
|---|---|
| Pages (from-to) | 1743-1750 |
| Number of pages | 8 |
| Journal | AIP Conference Proceedings |
| Volume | 1096 |
| DOIs | |
| State | Published - 2009 |
| Event | Review of Progress in Quantitative Nondestructive Evaluation - Chicago, IL, United States Duration: Jul 20 2008 → Jul 25 2008 |
All Science Journal Classification (ASJC) codes
- General Physics and Astronomy
Fingerprint
Dive into the research topics of 'Stepped ultrasonic array for inspection of submersed plates in a harsh environment'. Together they form a unique fingerprint.Cite this