TY - JOUR
T1 - Systematic, unintended drifts in the cyclic force produced with the fingertips
AU - Ambike, Satyajit
AU - Mattos, Daniela
AU - Zatsiorsky, Vladimir
AU - Latash, Mark
N1 - Funding Information:
The study was in part supported by National Institutes of Health Grants NS-035032 and AR-048563.
Publisher Copyright:
© 2018 Human Kinetics, Inc.
PY - 2018/1
Y1 - 2018/1
N2 - Cyclic isometric finger-force patterns established using visual feedback show systematic drifts when the feedback is removed. Force changes at multiple time scales and in opposite directions have been reported. For further characterization of these drifts, healthy subjects produced isometric, cyclic finger force with and without visual feedback at various initial amplitudes and frequencies. We hypothesized that on feedback removal, the amplitude will be attracted toward a preferred value that is frequency dependent. We found that the amplitude always increased after feedback removal. The magnitude of the amplitude increase changed with initial frequency, but it was invariant over the explored range of initial amplitudes. Thus, the existence of a preferred amplitude of force oscillations was not supported. We interpret these results within the referent configuration and the referent configuration back-coupling hypotheses. These data will inform a mathematical model of finger-force drifts. However, currently, they raise more questions than they answer, and a coherent account of fingerforce drifts remains a challenge.
AB - Cyclic isometric finger-force patterns established using visual feedback show systematic drifts when the feedback is removed. Force changes at multiple time scales and in opposite directions have been reported. For further characterization of these drifts, healthy subjects produced isometric, cyclic finger force with and without visual feedback at various initial amplitudes and frequencies. We hypothesized that on feedback removal, the amplitude will be attracted toward a preferred value that is frequency dependent. We found that the amplitude always increased after feedback removal. The magnitude of the amplitude increase changed with initial frequency, but it was invariant over the explored range of initial amplitudes. Thus, the existence of a preferred amplitude of force oscillations was not supported. We interpret these results within the referent configuration and the referent configuration back-coupling hypotheses. These data will inform a mathematical model of finger-force drifts. However, currently, they raise more questions than they answer, and a coherent account of fingerforce drifts remains a challenge.
UR - http://www.scopus.com/inward/record.url?scp=85042517519&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85042517519&partnerID=8YFLogxK
U2 - 10.1123/mc.2016-0082
DO - 10.1123/mc.2016-0082
M3 - Article
C2 - 28338400
AN - SCOPUS:85042517519
SN - 1087-1640
VL - 22
SP - 82
EP - 99
JO - Motor control
JF - Motor control
IS - 1
ER -