TY - JOUR
T1 - Tc-99m-BrIDA hepatobiliary (HIDA) scan has a low sensitivity for detecting biliary complications after orthotopic liver transplantation in patients with hyperbilirubinemia
AU - Hopkins, L. Olivia
AU - Feyssa, Eyob
AU - Parsikia, Afshin
AU - Khanmoradi, Kamran
AU - Zaki, Radi
AU - Campos, Stalin
AU - Araya, Victor
AU - Tran, Huyen
AU - Ortiz, Jorge
PY - 2011/12
Y1 - 2011/12
N2 - Background: Tc-99m-BrIDA hepatobiliary scans are noninvasive tests for detecting biliary leaks and obstructions. However, there is low sensitivity and specificity in patients with hyperbilirubinemia. Biliary complications (BC) are the Achilles heel of orthotopic liver transplantation (OLT). We questioned whether hyperbilirubinemia in liver transplant recipients rendered HIDA scanning less dependable. Methods: HIDA findings were compared to endoscopic retrograde cholangiopancreatography, laparotomy, and clinical course. Results were categorized as follows: true positive (TP), true negative (TN), false positive (FP), false negative (FN), or nondiagnostic/inconclusive. We searched for variables associated with erroneous or nondiagnostic tests which we defined as all examinations determined to be FP, FN and/or nondiagnostic/inconclusive. Results: Thirty-four patients underwent a HIDA scan. The sensitivity and specificity were 70 and 100%. The sensitivity of HIDA improved to 100% in patients with a total bilirubin (TB) <5 mg/dl. Inconclusive and FN patients had a total bilirubin >5 mg/dl. One FN had a TB <5 mg/dl, but was determined inconclusive due to the roux-en-Y. Conclusion: HIDA scans performed when the total bilirubin was <5 mg/dl had a high sensitivity and specificity for detecting biliary complications after OLT. However, when the total bilirubin exceeded 5 mg/dl, the specificity was still 100% but the numbers of nondiagnostic/inconclusive and FN exams were increased.
AB - Background: Tc-99m-BrIDA hepatobiliary scans are noninvasive tests for detecting biliary leaks and obstructions. However, there is low sensitivity and specificity in patients with hyperbilirubinemia. Biliary complications (BC) are the Achilles heel of orthotopic liver transplantation (OLT). We questioned whether hyperbilirubinemia in liver transplant recipients rendered HIDA scanning less dependable. Methods: HIDA findings were compared to endoscopic retrograde cholangiopancreatography, laparotomy, and clinical course. Results were categorized as follows: true positive (TP), true negative (TN), false positive (FP), false negative (FN), or nondiagnostic/inconclusive. We searched for variables associated with erroneous or nondiagnostic tests which we defined as all examinations determined to be FP, FN and/or nondiagnostic/inconclusive. Results: Thirty-four patients underwent a HIDA scan. The sensitivity and specificity were 70 and 100%. The sensitivity of HIDA improved to 100% in patients with a total bilirubin (TB) <5 mg/dl. Inconclusive and FN patients had a total bilirubin >5 mg/dl. One FN had a TB <5 mg/dl, but was determined inconclusive due to the roux-en-Y. Conclusion: HIDA scans performed when the total bilirubin was <5 mg/dl had a high sensitivity and specificity for detecting biliary complications after OLT. However, when the total bilirubin exceeded 5 mg/dl, the specificity was still 100% but the numbers of nondiagnostic/inconclusive and FN exams were increased.
UR - http://www.scopus.com/inward/record.url?scp=83855165775&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=83855165775&partnerID=8YFLogxK
U2 - 10.1007/s12149-011-0523-x
DO - 10.1007/s12149-011-0523-x
M3 - Article
C2 - 21845382
AN - SCOPUS:83855165775
SN - 0914-7187
VL - 25
SP - 762
EP - 767
JO - Annals of Nuclear Medicine
JF - Annals of Nuclear Medicine
IS - 10
ER -