TY - JOUR
T1 - Temporal resolution in electrochemical imaging on single PC12 cells using amperometry and voltammetry at microelectrode Arrays
AU - Zhang, Bo
AU - Heien, Michael L.A.V.
AU - Santillo, Michael F.
AU - Mellander, Lisa
AU - Ewing, Andrew G.
PY - 2011/1/15
Y1 - 2011/1/15
N2 - Carbon-fiber-microelectrode arrays (MEAs) have been utilized to electrochemically image neurochemical secretion from individual pheochromocytoma (PC12) cells. Dopamine release events were electrochemically monitored from seven different locations on single PC12 cells using alternately constant-potential amperometry and fast-scan cyclic voltammetry (FSCV). Cyclic voltammetry, when compared to amperometry, can provide excellent chemical resolution; however, spatial and temporal resolution are both compromised. The spatial and temporal resolution of these two methods have been quantitatively compared and the differences explained using models of molecular diffusion at the nanogap between the electrode and the cell. A numerical simulation of the molecular flux reveals that the diffusion of dopamine molecules and electrochemical reactions both play important roles in the temporal resolution of electrochemical imaging. The simulation also reveals that the diffusion and electrode potential cause the differences in signal crosstalk between electrodes when comparing amperometry and FSCV.
AB - Carbon-fiber-microelectrode arrays (MEAs) have been utilized to electrochemically image neurochemical secretion from individual pheochromocytoma (PC12) cells. Dopamine release events were electrochemically monitored from seven different locations on single PC12 cells using alternately constant-potential amperometry and fast-scan cyclic voltammetry (FSCV). Cyclic voltammetry, when compared to amperometry, can provide excellent chemical resolution; however, spatial and temporal resolution are both compromised. The spatial and temporal resolution of these two methods have been quantitatively compared and the differences explained using models of molecular diffusion at the nanogap between the electrode and the cell. A numerical simulation of the molecular flux reveals that the diffusion of dopamine molecules and electrochemical reactions both play important roles in the temporal resolution of electrochemical imaging. The simulation also reveals that the diffusion and electrode potential cause the differences in signal crosstalk between electrodes when comparing amperometry and FSCV.
UR - http://www.scopus.com/inward/record.url?scp=78751505505&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=78751505505&partnerID=8YFLogxK
U2 - 10.1021/ac102502g
DO - 10.1021/ac102502g
M3 - Article
C2 - 21190375
AN - SCOPUS:78751505505
SN - 0003-2700
VL - 83
SP - 571
EP - 577
JO - Analytical Chemistry
JF - Analytical Chemistry
IS - 2
ER -