TY - GEN
T1 - The effect of area ratio change via increased hole length for shaped film cooling holes with constant expansion angles
AU - Haydt, Shane
AU - Lynch, Stephen P.
AU - Lewis, Scott
PY - 2017/1/1
Y1 - 2017/1/1
N2 - Shaped film cooling holes are used as a cooling technology in gas turbines to reduce metal temperatures and improve durability, and they generally consist of a small metering section connected to a diffuser that expands in one or more directions. The area ratio of these holes is defined as the area at the exit of the diffuser, divided by the area at the metering section. A larger area ratio increases the diffusion of the coolant momentum, leading to lower average momentum of the coolant jet at the exit of the hole and generally better cooling performance. Cooling holes with larger area ratios are also more tolerant of high blowing ratio conditions, and the increased coolant diffusion typically better prevents jet liftoff from occurring. Higher area ratios have traditionally been accomplished by increasing the expansion angle of the diffuser while keeping the overall length of the hole constant. The present study maintains the diffuser expansion angles and instead increases the length of the diffuser, which results in longer holes. Various area ratios have been examined for two shaped holes: one with forward and lateral expansion angles of 7° (7-7-7 hole) and one with forward and lateral expansion angles of 12° (12-12-12 hole). Each hole shape was tested at numerous blowing ratios to capture trends across various flow rates. Adiabatic effectiveness measurements indicate that for the baseline 7-7-7 hole, a larger area ratio provides higher effectiveness, especially at higher blowing ratios. Measurements also indicate that for the 12-12-12 hole, a larger area ratio performs better at high blowing ratios but the hole experiences ingestion at low blowing ratios. Steady RANS simulations did not accurately predict the levels of adiabatic effectiveness, but did predict the trend of improving effectiveness with increasing area ratio for both hole shapes. Flowfield measurements with PIV were also performed at one downstream plane for a low and high area ratio case, and the results indicate an expected decrease in jet velocity due to a larger diffuser.
AB - Shaped film cooling holes are used as a cooling technology in gas turbines to reduce metal temperatures and improve durability, and they generally consist of a small metering section connected to a diffuser that expands in one or more directions. The area ratio of these holes is defined as the area at the exit of the diffuser, divided by the area at the metering section. A larger area ratio increases the diffusion of the coolant momentum, leading to lower average momentum of the coolant jet at the exit of the hole and generally better cooling performance. Cooling holes with larger area ratios are also more tolerant of high blowing ratio conditions, and the increased coolant diffusion typically better prevents jet liftoff from occurring. Higher area ratios have traditionally been accomplished by increasing the expansion angle of the diffuser while keeping the overall length of the hole constant. The present study maintains the diffuser expansion angles and instead increases the length of the diffuser, which results in longer holes. Various area ratios have been examined for two shaped holes: one with forward and lateral expansion angles of 7° (7-7-7 hole) and one with forward and lateral expansion angles of 12° (12-12-12 hole). Each hole shape was tested at numerous blowing ratios to capture trends across various flow rates. Adiabatic effectiveness measurements indicate that for the baseline 7-7-7 hole, a larger area ratio provides higher effectiveness, especially at higher blowing ratios. Measurements also indicate that for the 12-12-12 hole, a larger area ratio performs better at high blowing ratios but the hole experiences ingestion at low blowing ratios. Steady RANS simulations did not accurately predict the levels of adiabatic effectiveness, but did predict the trend of improving effectiveness with increasing area ratio for both hole shapes. Flowfield measurements with PIV were also performed at one downstream plane for a low and high area ratio case, and the results indicate an expected decrease in jet velocity due to a larger diffuser.
UR - http://www.scopus.com/inward/record.url?scp=85029080187&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85029080187&partnerID=8YFLogxK
U2 - 10.1115/GT2017-63692
DO - 10.1115/GT2017-63692
M3 - Conference contribution
AN - SCOPUS:85029080187
T3 - Proceedings of the ASME Turbo Expo
BT - Heat Transfer
PB - American Society of Mechanical Engineers (ASME)
T2 - ASME Turbo Expo 2017: Turbomachinery Technical Conference and Exposition, GT 2017
Y2 - 26 June 2017 through 30 June 2017
ER -