TY - JOUR
T1 - The effect of elbow position on the radial pulse measured by Doppler ultrasonography after surgical treatment of supracondylar elbow fractures in children
AU - Mapes, Randall C.
AU - Hennrikus, William L.
PY - 1998
Y1 - 1998
N2 - We performed a prospective study of 20 patients with displaced extension supracondylar humerus fractures and evaluated the effect of elbow flexion, forearm supination, and forearm pronation on blood flow to the injured arm after closed reduction and Kirschner wire fixation. Ten patients had a Gartland type II fracture and 10 patients had a Gartland type III fracture. After closed reduction and percutaneous pinning, the radial pulse was examined with Doppler ultrasonography starting with the elbow in extension. The elbow was slowly flexed, and the angle of elbow flexion at which the radial pulse disappeared was determined. This angle of elbow flexion was measured with the forearm in both supination and pronation. Gartland type III fractures demonstrated less elbow flexion prior to radial pulse ablation compared to Gartland type II fractures when the forearm was placed in supination (p = 0.001) and in pronation (p = 0.005). Supination allowed ≤5°of elbow flexion prior to radial pulse ablation in six Gartland type II and four Gartland type III fractures. We concluded that after closed reduction and percutaneous Kirschner wire fixation of displaced extension supracondylar fractures, vascular safety is enhanced by extending the elbow and supinating the forearm. The ideal position of elbow immobilization depends on the amount of swelling and the presence of a radial pulse.
AB - We performed a prospective study of 20 patients with displaced extension supracondylar humerus fractures and evaluated the effect of elbow flexion, forearm supination, and forearm pronation on blood flow to the injured arm after closed reduction and Kirschner wire fixation. Ten patients had a Gartland type II fracture and 10 patients had a Gartland type III fracture. After closed reduction and percutaneous pinning, the radial pulse was examined with Doppler ultrasonography starting with the elbow in extension. The elbow was slowly flexed, and the angle of elbow flexion at which the radial pulse disappeared was determined. This angle of elbow flexion was measured with the forearm in both supination and pronation. Gartland type III fractures demonstrated less elbow flexion prior to radial pulse ablation compared to Gartland type II fractures when the forearm was placed in supination (p = 0.001) and in pronation (p = 0.005). Supination allowed ≤5°of elbow flexion prior to radial pulse ablation in six Gartland type II and four Gartland type III fractures. We concluded that after closed reduction and percutaneous Kirschner wire fixation of displaced extension supracondylar fractures, vascular safety is enhanced by extending the elbow and supinating the forearm. The ideal position of elbow immobilization depends on the amount of swelling and the presence of a radial pulse.
UR - http://www.scopus.com/inward/record.url?scp=0031717769&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0031717769&partnerID=8YFLogxK
U2 - 10.1097/00004694-199807000-00006
DO - 10.1097/00004694-199807000-00006
M3 - Article
C2 - 9661848
AN - SCOPUS:0031717769
SN - 0271-6798
VL - 18
SP - 441
EP - 444
JO - Journal of Pediatric Orthopaedics
JF - Journal of Pediatric Orthopaedics
IS - 4
ER -