TY - JOUR
T1 - The efficacy of ultrasound in the diagnosis of long head of the biceps tendon pathology
AU - Armstrong, April
AU - Teefey, Sharlene A.
AU - Wu, Thomas
AU - Clark, Aileen M.
AU - Middleton, William D.
AU - Yamaguchi, Ken
AU - Galatz, Leesa M.
N1 - Funding Information:
This study was supported by a grant from the Society of Ultrasound Radiologists, awarded in 1998 ($40,000).
Copyright:
Copyright 2008 Elsevier B.V., All rights reserved.
PY - 2006/1
Y1 - 2006/1
N2 - The use of shoulder ultrasound as an imaging modality has recently gained widespread attention; however, the ability of ultrasound to diagnose long head of the biceps tendon pathology accurately still remains unclear. The biceps tendons in 71 patients were prospectively evaluated by comparison of standard ultrasonographic and arthroscopic examinations. Arthroscopic examination was used as the gold standard comparison. Ultrasound showed a 100% specificity and 96% sensitivity for subluxation or dislocation. Ultrasound detected all complete ruptures of the biceps tendon but detected none of the 23 partial-thickness tears. Overall, ultrasound diagnosed 35 of 36 normal biceps tendons (specificity, 97%) and 17 of 35 abnormal biceps tendons (sensitivity, 49%). Ultrasound can reliably diagnose complete rupture, subluxation, or dislocation of the biceps tendon. It is not reliable for detecting intraarticular partial-thickness tears.
AB - The use of shoulder ultrasound as an imaging modality has recently gained widespread attention; however, the ability of ultrasound to diagnose long head of the biceps tendon pathology accurately still remains unclear. The biceps tendons in 71 patients were prospectively evaluated by comparison of standard ultrasonographic and arthroscopic examinations. Arthroscopic examination was used as the gold standard comparison. Ultrasound showed a 100% specificity and 96% sensitivity for subluxation or dislocation. Ultrasound detected all complete ruptures of the biceps tendon but detected none of the 23 partial-thickness tears. Overall, ultrasound diagnosed 35 of 36 normal biceps tendons (specificity, 97%) and 17 of 35 abnormal biceps tendons (sensitivity, 49%). Ultrasound can reliably diagnose complete rupture, subluxation, or dislocation of the biceps tendon. It is not reliable for detecting intraarticular partial-thickness tears.
UR - http://www.scopus.com/inward/record.url?scp=30744458098&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=30744458098&partnerID=8YFLogxK
U2 - 10.1016/j.jse.2005.04.008
DO - 10.1016/j.jse.2005.04.008
M3 - Article
C2 - 16414462
AN - SCOPUS:30744458098
SN - 1058-2746
VL - 15
SP - 7
EP - 11
JO - Journal of Shoulder and Elbow Surgery
JF - Journal of Shoulder and Elbow Surgery
IS - 1
ER -