TY - JOUR
T1 - The ion-gas-neutral interactions with surfaces-2 (IGNIS-2) facility for the study of plasma-material interactions
AU - Schamis, Hanna
AU - Jaramillo-Correa, Camilo
AU - Parsons, Matthew S.
AU - Marchhart, Trevor
AU - Allain, Jean Paul
AU - Hargrove, Chase
AU - Judge, Aidan
AU - Kawashimo, Kenta
AU - Kunz, Ethan
AU - López Pérez, Camila
AU - Nieto-Perez, Martin
AU - Shober, Haiden
N1 - Publisher Copyright:
© 2024 Author(s).
PY - 2024/4/1
Y1 - 2024/4/1
N2 - The Ion-Gas-Neutral Interactions with Surfaces-2 (IGNIS-2) surface science facility has been designed at the Pennsylvania State University with the specific purpose of enabling experiments to study plasma-material interactions. This in situ surface modification and characterization facility consists of multiple reconfigurable substations that are connected through a central transfer chamber. This fully connected vacuum system ensures that the physical and chemical properties of samples are not altered between surface modification and analysis. The modification techniques in IGNIS-2 include a low-energy (<300 eV), high-flux (up to 1016 cm−2 s−1) broad-beam ion source, a liquid metal dropper, a lithium injection system, an RF sputter source, and an evaporator. Its characterization techniques include charged particle-based techniques, such as low-energy ion scattering (enabled by two < 5 keV ion sources) and x-ray photoelectron spectroscopy, and photon and light-based techniques, such as x-ray fluorescence, multi-beam optical stress sensors, and optical cameras. All of these techniques can be utilized up to mTorr pressures, allowing both in situ and in operando studies to be conducted. Results are presented on lithium wetting experiments of argon-irradiated tungsten-based composites, surface stress measurements of tungsten films during deuterium ion irradiation, and temperature-programmed desorption of deuterium-irradiated graphite to demonstrate the in situ capabilities of this new facility.
AB - The Ion-Gas-Neutral Interactions with Surfaces-2 (IGNIS-2) surface science facility has been designed at the Pennsylvania State University with the specific purpose of enabling experiments to study plasma-material interactions. This in situ surface modification and characterization facility consists of multiple reconfigurable substations that are connected through a central transfer chamber. This fully connected vacuum system ensures that the physical and chemical properties of samples are not altered between surface modification and analysis. The modification techniques in IGNIS-2 include a low-energy (<300 eV), high-flux (up to 1016 cm−2 s−1) broad-beam ion source, a liquid metal dropper, a lithium injection system, an RF sputter source, and an evaporator. Its characterization techniques include charged particle-based techniques, such as low-energy ion scattering (enabled by two < 5 keV ion sources) and x-ray photoelectron spectroscopy, and photon and light-based techniques, such as x-ray fluorescence, multi-beam optical stress sensors, and optical cameras. All of these techniques can be utilized up to mTorr pressures, allowing both in situ and in operando studies to be conducted. Results are presented on lithium wetting experiments of argon-irradiated tungsten-based composites, surface stress measurements of tungsten films during deuterium ion irradiation, and temperature-programmed desorption of deuterium-irradiated graphite to demonstrate the in situ capabilities of this new facility.
UR - http://www.scopus.com/inward/record.url?scp=85190869641&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85190869641&partnerID=8YFLogxK
U2 - 10.1063/5.0165857
DO - 10.1063/5.0165857
M3 - Article
C2 - 38629925
AN - SCOPUS:85190869641
SN - 0034-6748
VL - 95
JO - Review of Scientific Instruments
JF - Review of Scientific Instruments
IS - 4
M1 - 043508
ER -