T1 - Time-resolved fast-neutron radiography of air-water two-phase flows in a rectangular channel by an improved detection system
AU - Zboray, Robert
AU - Dangendorf, Volker
AU - Mor, Ilan
AU - Bromberger, Benjamin
AU - Tittelmeier, Kai
N1 - Publisher Copyright:
© 2015 AIP Publishing LLC.
PY - 2015/7/1
Y1 - 2015/7/1
N2 - In a previous work, we have demonstrated the feasibility of high-frame-rate, fast-neutron radiography of generic air-water two-phase flows in a 1.5 cm thick, rectangular flow channel. The experiments have been carried out at the high-intensity, white-beam facility of the Physikalisch-Technische Bundesanstalt, Germany, using an multi-frame, time-resolved detector developed for fast neutron resonance radiography. The results were however not fully optimal and therefore we have decided to modify the detector and optimize it for the given application, which is described in the present work. Furthermore, we managed to improve the image post-processing methodology and the noise suppression. Using the tailored detector and the improved post-processing, significant increase in the image quality and an order of magnitude lower exposure times, down to 3.33 ms, have been achieved with minimized motion artifacts. Similar to the previous study, different two-phase flow regimes such as bubbly slug and churn flows have been examined. The enhanced imaging quality enables an improved prediction of two-phase flow parameters like the instantaneous volumetric gas fraction, bubble size, and bubble velocities. Instantaneous velocity fields around the gas enclosures can also be more robustly predicted using optical flow methods as previously.
AB - In a previous work, we have demonstrated the feasibility of high-frame-rate, fast-neutron radiography of generic air-water two-phase flows in a 1.5 cm thick, rectangular flow channel. The experiments have been carried out at the high-intensity, white-beam facility of the Physikalisch-Technische Bundesanstalt, Germany, using an multi-frame, time-resolved detector developed for fast neutron resonance radiography. The results were however not fully optimal and therefore we have decided to modify the detector and optimize it for the given application, which is described in the present work. Furthermore, we managed to improve the image post-processing methodology and the noise suppression. Using the tailored detector and the improved post-processing, significant increase in the image quality and an order of magnitude lower exposure times, down to 3.33 ms, have been achieved with minimized motion artifacts. Similar to the previous study, different two-phase flow regimes such as bubbly slug and churn flows have been examined. The enhanced imaging quality enables an improved prediction of two-phase flow parameters like the instantaneous volumetric gas fraction, bubble size, and bubble velocities. Instantaneous velocity fields around the gas enclosures can also be more robustly predicted using optical flow methods as previously.
UR - http://www.scopus.com/inward/record.url?scp=84937458892&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84937458892&partnerID=8YFLogxK
U2 - 10.1063/1.4926999
DO - 10.1063/1.4926999
M3 - Article
AN - SCOPUS:84937458892
SN - 0034-6748
VL - 86
JO - Review of Scientific Instruments
JF - Review of Scientific Instruments
IS - 7
M1 - 075103
ER -