T1 - Transcatheter Heart Valve Downstream Fluid Dynamics in an Accelerated Evaluation Environment
AU - Ponnaluri, Sailahari V.
AU - Deutsch, Steven
AU - Sacks, Michael S.
AU - Manning, Keefe B.
N1 - Funding Information:
This research was supported by NIH HL129077 and the Leighton Riess Graduate Fellowship in Engineering from the Penn State Center for Biodevices.
Publisher Copyright:
© 2021, Biomedical Engineering Society.
PY - 2021/9
Y1 - 2021/9
N2 - Transcatheter aortic valve replacements (TAVRs) provide minimally invasive delivery of bioprosthetic heart valves (BHVs) for the treatment of aortic valve disease. While surgical BHVs show efficacy for 8-10 years, long-term TAVR durability remains unknown. Pre-clinical testing evaluates BHV durability in an ISO:5840 compliant accelerated wear tester (AWT), yet, the design and development of AWTs and their accuracy in predicting in vivo performance, is unclear. As a result of limited knowledge on AWT environment and BHV loading, durability assessment of candidate valves remains fundamentally empirical. For the first time, high-speed particle image velocimetry quantified an ISO:5840 compliant downstream AWT velocity field, Reynolds stresses, and turbulence intensity. TAVR enface imaging quantified the orifice area and estimated the flow rate. When valve area and flow rate were at their maximum during peak systole (1.49 cm2 and 16.05 L/min, respectively), central jet velocity, Reynolds normal and shear stress, and turbulence intensity grew to 0.50 m/s, 265.1 Pa, 124.6 Pa, and 37.3%, respectively. During diastole, unique AWT recirculation produced retrograde flow and the directional changes created eddies. These novel AWT findings demonstrated a substantially reduced valve fully loaded period and pressure not matching in vivo or in vitro studies, despite the comparable fluid environment and TAVR motion.
AB - Transcatheter aortic valve replacements (TAVRs) provide minimally invasive delivery of bioprosthetic heart valves (BHVs) for the treatment of aortic valve disease. While surgical BHVs show efficacy for 8-10 years, long-term TAVR durability remains unknown. Pre-clinical testing evaluates BHV durability in an ISO:5840 compliant accelerated wear tester (AWT), yet, the design and development of AWTs and their accuracy in predicting in vivo performance, is unclear. As a result of limited knowledge on AWT environment and BHV loading, durability assessment of candidate valves remains fundamentally empirical. For the first time, high-speed particle image velocimetry quantified an ISO:5840 compliant downstream AWT velocity field, Reynolds stresses, and turbulence intensity. TAVR enface imaging quantified the orifice area and estimated the flow rate. When valve area and flow rate were at their maximum during peak systole (1.49 cm2 and 16.05 L/min, respectively), central jet velocity, Reynolds normal and shear stress, and turbulence intensity grew to 0.50 m/s, 265.1 Pa, 124.6 Pa, and 37.3%, respectively. During diastole, unique AWT recirculation produced retrograde flow and the directional changes created eddies. These novel AWT findings demonstrated a substantially reduced valve fully loaded period and pressure not matching in vivo or in vitro studies, despite the comparable fluid environment and TAVR motion.
UR - http://www.scopus.com/inward/record.url?scp=85101775248&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85101775248&partnerID=8YFLogxK
U2 - 10.1007/s10439-021-02751-w
DO - 10.1007/s10439-021-02751-w
M3 - Article
C2 - 33638029
AN - SCOPUS:85101775248
SN - 0090-6964
VL - 49
SP - 2170
EP - 2182
JO - Annals of Biomedical Engineering
JF - Annals of Biomedical Engineering
IS - 9
ER -