T1 - Transmission of water through a biocompatible polyurethane
T2 - Application to circulatory assist devices
AU - Reid, J. Spence
AU - Rosenberg, Gerson
AU - Pierce, William S.
PY - 1985
Y1 - 1985
N2 - The permeability characteristics of a water‐segmented polyurethane (Biomer) system under the conditions encountered in circulatory‐assist devices were investigated. A diffusion cell and permeability system providing precise control of membrane boundary conditions and allowing continuous measurement of water vapor transmission was designed. Liquid water at 37°C was used as the donor fluid and the system incorporated a constant‐flow nitrogen carrier gas and an optical dew point sensor downstream to determine the water vapor mass flow rate as a function of time. The mass flow rate was then numerically integrated and plotted against time to allow calculation of effective diffusion coefficient (D) by the dynamic time lag method. Steady‐state permeabilities were found to be insensitive to donor chamber hydrostatic pressure (50–200 mm Hg) indicating that bulk flow is not a transport mechanism in these membranes. The permeability coefficient (P) was independent of membrane thickness (H) over the four samples tested (0.0102, 0.0148, 0.0269, and 0.0366 cm), with an average value of 3.29 × 10−4cm2/s. Thus, diffusion was Fickian with negligible boundary layers. A plot of lag time versus H2 was linear (R = 0.98) yielding a value for D of 2.18 × 10−7cm2/s. A water–Biomer partition coefficient was determined for each sample with an average value of 1525, indicating a moderately hydrophilic membrane with a water sorption of 6.3% at 37°C. Since water transport is by Fickian diffusion in the absence of bulk flow, liquid water cannot be expected to accumulate in circulatory‐assist devices unless a condensing surface is maintained within the system.
AB - The permeability characteristics of a water‐segmented polyurethane (Biomer) system under the conditions encountered in circulatory‐assist devices were investigated. A diffusion cell and permeability system providing precise control of membrane boundary conditions and allowing continuous measurement of water vapor transmission was designed. Liquid water at 37°C was used as the donor fluid and the system incorporated a constant‐flow nitrogen carrier gas and an optical dew point sensor downstream to determine the water vapor mass flow rate as a function of time. The mass flow rate was then numerically integrated and plotted against time to allow calculation of effective diffusion coefficient (D) by the dynamic time lag method. Steady‐state permeabilities were found to be insensitive to donor chamber hydrostatic pressure (50–200 mm Hg) indicating that bulk flow is not a transport mechanism in these membranes. The permeability coefficient (P) was independent of membrane thickness (H) over the four samples tested (0.0102, 0.0148, 0.0269, and 0.0366 cm), with an average value of 3.29 × 10−4cm2/s. Thus, diffusion was Fickian with negligible boundary layers. A plot of lag time versus H2 was linear (R = 0.98) yielding a value for D of 2.18 × 10−7cm2/s. A water–Biomer partition coefficient was determined for each sample with an average value of 1525, indicating a moderately hydrophilic membrane with a water sorption of 6.3% at 37°C. Since water transport is by Fickian diffusion in the absence of bulk flow, liquid water cannot be expected to accumulate in circulatory‐assist devices unless a condensing surface is maintained within the system.
UR - http://www.scopus.com/inward/record.url?scp=0022162267&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0022162267&partnerID=8YFLogxK
U2 - 10.1002/jbm.820190924
DO - 10.1002/jbm.820190924
M3 - Article
C2 - 4086496
AN - SCOPUS:0022162267
SN - 0021-9304
VL - 19
SP - 1181
EP - 1202
JO - Journal of Biomedical Materials Research
JF - Journal of Biomedical Materials Research
IS - 9
ER -