USE OF LOW-MOISTURE-PERMEABILITY INSULATION AS AN EXTERIOR RETROFIT SYSTEM - A CONDENSATION STUDY.

Douglas M. Burch, Antonio G. Contreras, Stephen James Treado

Research output: Contribution to journalConference articlepeer-review

4 Scopus citations

Abstract

Laboratory and field studies were carried out to determine the use of low-moisture-permeability insulation as an exterior retrofit system increases winter moisture accumulation within the existing wood siding, sheathing, and cavity insulation. A full-scale insulated test wall was sandwiched between a hot and cold box apparatus in the laboratory. The exterior surface of one half of this test wall was fitted with a low-permeability insulation retrofit system. The moisture-transfer processes which occurred in the test wall were modeled with an ASHRAE diffusion model modified with a term to account for air leakage from the hot to the cold box. A field survey of several wall constructions was carried out to compare field observations of moisture conditions with laboratory results.

Original languageEnglish (US)
Pages (from-to)547-562
Number of pages16
JournalASHRAE Transactions
Volume85
Issue numberPt 2
StatePublished - Jan 1 1979
EventTech and Symp Pap Presented at the Annu Meet - Detroit, MI, Engl
Duration: Jun 24 1979Jun 28 1979

All Science Journal Classification (ASJC) codes

  • Building and Construction
  • Mechanical Engineering

Fingerprint

Dive into the research topics of 'USE OF LOW-MOISTURE-PERMEABILITY INSULATION AS AN EXTERIOR RETROFIT SYSTEM - A CONDENSATION STUDY.'. Together they form a unique fingerprint.

Cite this