Validation of continuous thermodilution cardiac output in patients implanted with a left ventricular assist device

B. Mets, R. J. Frumento, E. Bennett-Guerrero, Y. Naka

Research output: Contribution to journalArticlepeer-review

13 Scopus citations

Abstract

Objective: To assess the accuracy of a continuous cardiac output (CCO) monitor against an independent, intravascular measurement of flow as can be performed in patients fitted with a left ventricular assist device (LVAD). Design: A prospective cohort study. Setting: Academic tertiary-care center. Participants: Adult patients (n = 15) presenting for LVAD placement. Interventions: Consenting patients presenting for LVAD placement for end-stage cardiac failure were anesthetized, and a CCO pulmonary artery catheter was placed (OptiQ, CCO/SvO2; Abbott Critical Care, North Chicago, IL). Patients were monitored with transesophageal echocardiography and excluded from analysis if aortic regurgitation was found. Cardiac output was determined using a Q-Vue, CCO/SvO2 computer with digital readout (Abbott Critical Care, North Chicago, IL). The LVAD was placed in standard fashion during cardiopulmonary bypass. The Thoratec vented electric Heartmate (Thoratec Co, Pleasanton, CA) incorporates an LVAD flow console, which computes LVAD flow within ± 5% (range, 1.8 to 10 L/min). Measurements and Main Results: Cardiac output flow measurements were made from both systems at the following time points: 5 minutes and 30 minutes after protamine administration, at chest closure, and after skin closure. Mean cardiac output for each device did not differ at any time point. Regression analysis (Pearson's) showed acceptable correlation (r2 = 0.79, p < 0.0001), whereas a bias of 529 mL with limits of agreement of 1,208 mL were shown for CCO measurement compared with LVAD flow. Conclusion: The data indicate that the CCO system tends to overestimate cardiac output by approximately 500 mL/min when compared with LVAD flow. Nevertheless, this bias is within the range found by other less-invasive studies done to assess the accuracy of this system and further serves to confirm its relative accuracy.

Original languageEnglish (US)
Pages (from-to)727-730
Number of pages4
JournalJournal of cardiothoracic and vascular anesthesia
Volume16
Issue number6
DOIs
StatePublished - Dec 2002

All Science Journal Classification (ASJC) codes

  • Cardiology and Cardiovascular Medicine
  • Anesthesiology and Pain Medicine

Fingerprint

Dive into the research topics of 'Validation of continuous thermodilution cardiac output in patients implanted with a left ventricular assist device'. Together they form a unique fingerprint.

Cite this