T1 - Validity of conventional radiography in determining scaphoid waist fracture displacement
AU - Bernard, Stephanie A.
AU - Murray, Peter M.
AU - Heckman, Michael G.
N1 - Copyright:
Copyright 2011 Elsevier B.V., All rights reserved.
PY - 2010/7
Y1 - 2010/7
N2 - Objective: This study examines interpreter accuracy and interobserver agreement in evaluating conventional radiographs for scaphoid waist fracture displacement. Methods: Six fresh-frozen cadaver arms were obtained transected above the elbow. A waist fracture was created in each scaphoid. In a random fashion, three of the fractures were displaced 1 mm in the radial-ulnar plane, whereas the other three were reapproximated to anatomic position before all fractures were stabilized with radiolucent adhesive glue. A three-view conventional radiography series consisting of a posterior-anterior, lateral, and ulnar-deviated elongated scaphoid view was obtained for each wrist. Each radiograph was then presented in the same sequence for interpretation to six independent observers: two hand surgeons, two musculoskeletal radiologists, and two senior orthopaedic surgery residents who were all blinded to the actual fracture pattern. Results: In 14 of the 18 (78%) displaced fracture radiographic series, the interpreters correctly recognized displacement being present. However, displacement was also reported in six of the 18 (33%) nondisplaced fracture series. The estimated overall accuracy of all readings for distinguishing between displaced and nondisplaced fractures was 72%. Of the 90 total possible pairwise agreements between interpreters regarding fracture displacement, there were 54 actual agreements (60%), and kappa was estimated to be 0.31. Taken together, these two measures of agreement can be interpreted as indicating poor to moderate agreement. Conclusion: Our results suggest that conventional radiography is not reliable in determining 1-mm scaphoid waist fracture displacement in the radioulnar plane and also indicated a lack of strong interobserver agreement.
AB - Objective: This study examines interpreter accuracy and interobserver agreement in evaluating conventional radiographs for scaphoid waist fracture displacement. Methods: Six fresh-frozen cadaver arms were obtained transected above the elbow. A waist fracture was created in each scaphoid. In a random fashion, three of the fractures were displaced 1 mm in the radial-ulnar plane, whereas the other three were reapproximated to anatomic position before all fractures were stabilized with radiolucent adhesive glue. A three-view conventional radiography series consisting of a posterior-anterior, lateral, and ulnar-deviated elongated scaphoid view was obtained for each wrist. Each radiograph was then presented in the same sequence for interpretation to six independent observers: two hand surgeons, two musculoskeletal radiologists, and two senior orthopaedic surgery residents who were all blinded to the actual fracture pattern. Results: In 14 of the 18 (78%) displaced fracture radiographic series, the interpreters correctly recognized displacement being present. However, displacement was also reported in six of the 18 (33%) nondisplaced fracture series. The estimated overall accuracy of all readings for distinguishing between displaced and nondisplaced fractures was 72%. Of the 90 total possible pairwise agreements between interpreters regarding fracture displacement, there were 54 actual agreements (60%), and kappa was estimated to be 0.31. Taken together, these two measures of agreement can be interpreted as indicating poor to moderate agreement. Conclusion: Our results suggest that conventional radiography is not reliable in determining 1-mm scaphoid waist fracture displacement in the radioulnar plane and also indicated a lack of strong interobserver agreement.
UR - http://www.scopus.com/inward/record.url?scp=77955689256&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=77955689256&partnerID=8YFLogxK
U2 - 10.1097/BOT.0b013e3181c3e865
DO - 10.1097/BOT.0b013e3181c3e865
M3 - Article
C2 - 20577078
AN - SCOPUS:77955689256
SN - 0890-5339
VL - 24
SP - 448
EP - 451
JO - Journal of orthopaedic trauma
JF - Journal of orthopaedic trauma
IS - 7
ER -