TY - JOUR
T1 - Voice-Related Quality of Life Increases With a Talking Tracheostomy Tube
T2 - A Randomized Controlled Trial
AU - Pandian, Vinciya
AU - Cole, Therese
AU - Kilonsky, Dana
AU - Holden, Kate
AU - Feller-Kopman, David J.
AU - Brower, Roy
AU - Mirski, Marek
N1 - Publisher Copyright:
© 2019 The American Laryngological, Rhinological and Otological Society, Inc.
PY - 2020/5/1
Y1 - 2020/5/1
N2 - Objective: The primary objective of our study was to determine the quality of life (QOL) using a talking tracheostomy tube. Methods: Randomized clinical trial (NCT2018562). Adult intensive care unit patients who were mechanically ventilated, awake, alert, attempting to communicate, English-speaking, and could not tolerate one-way speaking valve were included. Intervention comprised a Blue Line Ultra Suctionaid (BLUSA) talking tracheostomy tube (Smiths Medical, Dublin, OH, US). Outcome measures included QOL scores measured using Quality of Life in Mechanically Ventilated Patients (QOL-MV) and Voice-Related Quality of Life (V-RQOL), Speech Intelligibility Test (SIT) scores, independence, and satisfaction. Results: The change in V-RQOL scores from pre- to postintervention was higher among patients using a BLUSA (Smiths Medical) compared to those who did not (P = 0.001). The QOL-MV scores from pre- to postintervention were significantly higher among patients who used a BLUSA (Smiths Medical) compared to patients who did not use BLUSA (Smiths Medical) or a one-way speaking valve (P = 0.04). SIT scores decreased by 6.4 points for each 1-point increase in their Sequential Organ Failure Assessment scores (P = 0.04). The overall QOL-MV scores correlated moderately with the overall V-RQOL scores (correlation coefficient = 0.59). Cronbach alpha score for overall QOL-MV was 0.71. Seventy-three percent of the 22 intervention patients reported the ability to use the BLUSA (Smiths Medical) with some level of independence, whereas 41% reported some level of satisfaction with the use of BLUSA (Smiths Medical). The lengths of stay was longer in the intervention group. Conclusion: Our study suggests that BLUSA (Smiths Medical) talking tracheostomy tube improves patient-reported QOL in mechanically ventilated patients with a tracheostomy who cannot tolerate cuff deflation. Level of Evidence: I. Laryngoscope, 130:1249–1255, 2020.
AB - Objective: The primary objective of our study was to determine the quality of life (QOL) using a talking tracheostomy tube. Methods: Randomized clinical trial (NCT2018562). Adult intensive care unit patients who were mechanically ventilated, awake, alert, attempting to communicate, English-speaking, and could not tolerate one-way speaking valve were included. Intervention comprised a Blue Line Ultra Suctionaid (BLUSA) talking tracheostomy tube (Smiths Medical, Dublin, OH, US). Outcome measures included QOL scores measured using Quality of Life in Mechanically Ventilated Patients (QOL-MV) and Voice-Related Quality of Life (V-RQOL), Speech Intelligibility Test (SIT) scores, independence, and satisfaction. Results: The change in V-RQOL scores from pre- to postintervention was higher among patients using a BLUSA (Smiths Medical) compared to those who did not (P = 0.001). The QOL-MV scores from pre- to postintervention were significantly higher among patients who used a BLUSA (Smiths Medical) compared to patients who did not use BLUSA (Smiths Medical) or a one-way speaking valve (P = 0.04). SIT scores decreased by 6.4 points for each 1-point increase in their Sequential Organ Failure Assessment scores (P = 0.04). The overall QOL-MV scores correlated moderately with the overall V-RQOL scores (correlation coefficient = 0.59). Cronbach alpha score for overall QOL-MV was 0.71. Seventy-three percent of the 22 intervention patients reported the ability to use the BLUSA (Smiths Medical) with some level of independence, whereas 41% reported some level of satisfaction with the use of BLUSA (Smiths Medical). The lengths of stay was longer in the intervention group. Conclusion: Our study suggests that BLUSA (Smiths Medical) talking tracheostomy tube improves patient-reported QOL in mechanically ventilated patients with a tracheostomy who cannot tolerate cuff deflation. Level of Evidence: I. Laryngoscope, 130:1249–1255, 2020.
UR - http://www.scopus.com/inward/record.url?scp=85070753233&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85070753233&partnerID=8YFLogxK
U2 - 10.1002/lary.28211
DO - 10.1002/lary.28211
M3 - Article
C2 - 31385620
AN - SCOPUS:85070753233
SN - 0023-852X
VL - 130
SP - 1249
EP - 1255
JO - Laryngoscope
JF - Laryngoscope
IS - 5
ER -